4.6 Review

Contactless Vital Signs Monitoring From Videos Recorded With Digital Cameras: An Overview

Related references

Note: Only part of the references are listed.
Article Engineering, Biomedical

A Blood Pressure Prediction Method Based on Imaging Photoplethysmography in combination with Machine Learning

Meng Rong et al.

Summary: This paper introduces a non-contact blood pressure measurement system based on imaging photoplethysmography (IPPG) technology, which utilizes machine learning algorithms to train extracted pulse wave signals and selects the most accurate model for blood pressure prediction.

BIOMEDICAL SIGNAL PROCESSING AND CONTROL (2021)

Article Computer Science, Information Systems

Non-Contact HR Monitoring via Smartphone and Webcam During Different Respiratory Maneuvers and Body Movements

Monay Mokhtar Shoushan et al.

Summary: A camera-based heart rate monitoring technique proposed in this study extracts iPPG signals from video sequences to estimate heart rate information, achieving a high accuracy rate of 99.4% with only 0.56% error when compared to the gold-standard ECG reference in various motion and respiratory conditions.

IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS (2021)

Article Engineering, Biomedical

A non-contact camera-based method for respiratory rhythm extraction

M. Mateu-Mateus et al.

Summary: The study introduces a non-contact video-based method for extracting respiratory rhythm using a consumer-grade RGB camera and computer vision algorithms. The proposed method shows high correlation and sensitivity compared to a reference method, with low error rates, making it suitable for real-time respiratory signal acquisition in various situations.

BIOMEDICAL SIGNAL PROCESSING AND CONTROL (2021)

Article Computer Science, Information Systems

Camera-Based Vital Signs Monitoring During Sleep - A Proof of Concept Study

Mark van Gastel et al.

Summary: Polysomnography is currently the gold standard for diagnosing sleep disorders, but has limitations such as restricting patient mobility and requiring a visit to a specialized clinic. Remote photoplethysmography using video is an emerging technique for detecting sleep disorders without these drawbacks. Tested on patients with obstructive sleep apnea, the camera system showed promising accuracy in monitoring pulse, respiration, and blood oxygen saturation.

IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS (2021)

Article Engineering, Biomedical

The minimal sampling frequency of the photoplethysmogram for accurate pulse rate variability parameters in healthy volunteers

Szabolcs Beres et al.

Summary: The study found that a sampling frequency of 5 Hz may be sufficient for monitoring average heart rate in healthy subjects, while accurate HRV analysis requires higher sampling rates. Interpolation techniques can improve HRV accuracy from lower temporal resolution PPG signals.

BIOMEDICAL SIGNAL PROCESSING AND CONTROL (2021)

Article Chemistry, Analytical

Non-Contact Respiratory Monitoring Using an RGB Camera for Real-World Applications

Chiara Romano et al.

Summary: A low-cost respiratory pattern monitoring system based on RGB image analysis was proposed, showing good performance in tracking chest movements, extracting breathing signals, and eliminating irrelevant events. Testing in unstructured environments with varying user postures and distances yielded promising results for this system.

SENSORS (2021)

Review Chemistry, Analytical

A Review of Deep Learning-Based Contactless Heart Rate Measurement Methods

Aoxin Ni et al.

Summary: The study conducted a comparison of deep learning methods with publicly available codes for heart rate measurement, revealing that PhysNet generated the best outcome among these methods.

SENSORS (2021)

Article Chemistry, Analytical

Assessment of Non-Invasive Blood Pressure Prediction from PPG and rPPG Signals Using Deep Learning

Fabian Schrumpf et al.

Summary: Using photoplethysmography signals for non-invasive blood pressure measurement is interesting for various reasons, and machine learning techniques are commonly used with performances evaluated based on mean average error. Careful dataset assignment is crucial, and personalization techniques can significantly reduce prediction errors.

SENSORS (2021)

Article Engineering, Electrical & Electronic

Motion-Robust Multimodal Heart Rate Estimation Using BCG Fused Remote-PPG With Deep Facial ROI Tracker and Pose Constrained Kalman Filter

Yiming Liu et al.

Summary: This article introduces a novel multimodal quasi-contactless HR sensor that combines face and head motion disturbances and fuses rPPG and BCG signals for accurate heart rate estimation. Experimental comparisons demonstrate that the proposed sensor is more robust and accurate than the state-of-the-art single-modal sensors for heart rate estimation.

IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT (2021)

Article Orthopedics

Vascular Anatomy of the Hand in Relation to Flaps

Ruth En Si Tan et al.

HAND CLINICS (2020)

Review Chemistry, Analytical

Human Vital Signs Detection Methods and Potential Using Radars: A Review

Mamady Kebe et al.

SENSORS (2020)

Article Engineering, Electrical & Electronic

Noncontact SpO2 Measurement Using Eulerian Video Magnification

Alessandra de Fatima Galvao Rosa et al.

IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT (2020)

Article Physiology

Remote Respiratory Monitoring in the Time of COVID-19

Carlo Massaroni et al.

FRONTIERS IN PHYSIOLOGY (2020)

Article Chemistry, Analytical

Heartbeat Detection by Laser Doppler Vibrometry and Machine Learning

Luca Antognoli et al.

SENSORS (2020)

Article Pediatrics

Non-Contact Video-Based Neonatal Respiratory Monitoring

Scott L. Rossol et al.

CHILDREN-BASEL (2020)

Article Chemistry, Multidisciplinary

Real-Time Webcam Heart-Rate and Variability Estimation with Clean Ground Truth for Evaluation †

Amogh Gudi et al.

APPLIED SCIENCES-BASEL (2020)

Article Medical Informatics

Remote Patient Monitoring Program for Hospital Discharged COVID-19 Patients

William J. Gordon et al.

APPLIED CLINICAL INFORMATICS (2020)

Article Computer Science, Information Systems

Camera-Based Method for Respiratory Rhythm Extraction From a Lateral Perspective

Marc Mateu-Mateus et al.

IEEE ACCESS (2020)

Article Statistics & Probability

Contactless heart rate estimation from face videos

Puneet Singh Lamba et al.

JOURNAL OF STATISTICS AND MANAGEMENT SYSTEMS (2020)

Review Chemistry, Analytical

Contact-Based Methods for Measuring Respiratory Rate

Carlo Massaroni et al.

SENSORS (2019)

Article Engineering, Electrical & Electronic

Using video stream for continuous monitoring of breathing rate for general setting

Gaddisa Olani Ganfure

SIGNAL IMAGE AND VIDEO PROCESSING (2019)

Article Cardiac & Cardiovascular Systems

Smartphone-Based Blood Pressure Measurement Using Transdermal Optical Imaging Technology

Hong Luo et al.

CIRCULATION-CARDIOVASCULAR IMAGING (2019)

Article Computer Science, Information Systems

Heart Rate and Heart Rate Variability From Single-Channel Video and ICA Integration of Multiple Signals

Riccardo Favilla et al.

IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS (2019)

Review Chemistry, Multidisciplinary

Remote Monitoring of Vital Signs in Diverse Non-Clinical and Clinical Scenarios Using Computer Vision Systems: A Review

Fatema-Tuz-Zohra Khanam et al.

APPLIED SCIENCES-BASEL (2019)

Article Psychology, Mathematical

An open-source remote heart rate imaging method with practical apparatus and algorithms

Koen M. van der Kooij et al.

BEHAVIOR RESEARCH METHODS (2019)

Proceedings Paper Computer Science, Artificial Intelligence

Performance Evaluation of Visual Object Detection and Tracking Algorithms Used in Remote Photoplethysmography

Changchen Zhao et al.

2019 IEEE/CVF INTERNATIONAL CONFERENCE ON COMPUTER VISION WORKSHOPS (ICCVW) (2019)

Review Cardiac & Cardiovascular Systems

Cuff-Less Methods for Blood PressureTelemonitoring

Dylan M. Bard et al.

FRONTIERS IN CARDIOVASCULAR MEDICINE (2019)

Review Computer Science, Information Systems

Remote heart rate measurement using low-cost RGB face video: a technical literature review

Philipp V. Rouast et al.

FRONTIERS OF COMPUTER SCIENCE (2018)

Review Engineering, Biomedical

Cardiovascular assessment by imaging photoplethysmography - a review

Sebastian Zaunseder et al.

BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK (2018)

Article Engineering, Biomedical

Fusing Partial Camera Signals for Noncontact Pulse Rate Variability Measurement

Daniel J. McDuff et al.

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING (2018)

Review Engineering, Biomedical

Cardiovascular assessment by imaging photoplethysmography - a review

Sebastian Zaunseder et al.

BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK (2018)

Article Engineering, Biomedical

Algorithms for Monitoring Heart Rate and Respiratory Rate From the Video of a User's Face

Shourjya Sanyal et al.

IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE (2018)

Review Chemistry, Analytical

Wearable Health Devices-Vital Sign Monitoring, Systems and Technologies

Duarte Dias et al.

SENSORS (2018)

Article Engineering, Electrical & Electronic

Contactless Monitoring of Breathing Patterns and Respiratory Rate at the Pit of the Neck: A Single Camera Approach

Carlo Massaroni et al.

JOURNAL OF SENSORS (2018)

Review Biotechnology & Applied Microbiology

A Comparative Survey of Methods for Remote Heart Rate Detection From Frontal Face Videos

Chen Wang et al.

FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY (2018)

Article Engineering, Biomedical

Algorithmic Principles of Remote PPG

Wenjin Wang et al.

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING (2017)

Article Engineering, Multidisciplinary

Webcam-based, non-contact, real-time measurement for the physiological parameters of drivers

Qi Zhang et al.

MEASUREMENT (2017)

Article Computer Science, Information Systems

Tidal Volume and Instantaneous Respiration Rate Estimation using a Volumetric Surrogate Signal Acquired via a Smartphone Camera

Bersain A. Reyes et al.

IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS (2017)

Review Computer Science, Information Systems

Monitoring of Cardiorespiratory Signal: Principles of Remote Measurements and Review of Methods

Ali Al-Naji et al.

IEEE ACCESS (2017)

Article Computer Science, Interdisciplinary Applications

Analysis of breathing via optoelectronic systems: comparison of four methods for computing breathing volumes and thoraco-abdominal motion pattern

Carlo Massaroni et al.

COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING (2017)

Article Public, Environmental & Occupational Health

The PhysioCam: A Novel Non-Contact Sensor to Measure Heart Rate Variability in Clinical and Field Applications

Maria I. Davila et al.

FRONTIERS IN PUBLIC HEALTH (2017)

Review Engineering, Biomedical

Heart rate estimation using facial video: A review

M. A. Hassan et al.

BIOMEDICAL SIGNAL PROCESSING AND CONTROL (2017)

Article Construction & Building Technology

A pilot study of online non-invasive measuring technology based on video magnification to determine skin temperature

Xiaogang Cheng et al.

BUILDING AND ENVIRONMENT (2017)

Review Engineering, Multidisciplinary

Cuff-Less and Continuous Blood Pressure Monitoring: A Methodological Review

Manuja Sharma et al.

TECHNOLOGIES (2017)

Article Computer Science, Software Engineering

Contactless Cardiac Activity Detection Based on Head Motion Magnification

Ali Al-Naji et al.

INTERNATIONAL JOURNAL OF IMAGE AND GRAPHICS (2017)

Article Biophysics

Video-based respiration monitoring with automatic region of interest detection

Rik Janssen et al.

PHYSIOLOGICAL MEASUREMENT (2016)

Article Hematology

Camera-based photoplethysmography in critical care patients

S. Rasche et al.

CLINICAL HEMORHEOLOGY AND MICROCIRCULATION (2016)

Article Engineering, Biomedical

Noncontact Monitoring of Blood Oxygen Saturation Using Camera and Dual-Wavelength Imaging System

Dangdang Shao et al.

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING (2016)

Review Engineering, Biomedical

Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging

Yu Sun et al.

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING (2016)

Review Neurosciences

Respiratory Changes in Response to Cognitive Load: A Systematic Review

Mariel Grassmann et al.

NEURAL PLASTICITY (2016)

Article Geography, Physical

Improved wide-angle, fisheye and omnidirectional camera calibration

Steffen Urban et al.

ISPRS JOURNAL OF PHOTOGRAMMETRY AND REMOTE SENSING (2015)

Review Engineering, Biomedical

Flow measurement in mechanical ventilation: A review

Emiliano Schena et al.

MEDICAL ENGINEERING & PHYSICS (2015)

Article Computer Science, Information Systems

Estimation of Respiratory Rate From Photoplethysmographic Imaging Videos Compared to Pulse Oximetry

Walter Karlen et al.

IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS (2015)

Article Ergonomics

Evaluation of a video-based measure of driver heart rate

Jonny Kuo et al.

JOURNAL OF SAFETY RESEARCH (2015)

Article Medicine, General & Internal

Heart Rate Variability in Adolescents - Normative Data Stratified by Sex and Physical Activity

Vivek Kumar Sharma et al.

JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH (2015)

Review Engineering, Biomedical

Non-contact heart rate and heart rate variability measurements: A review

J. Kranjec et al.

BIOMEDICAL SIGNAL PROCESSING AND CONTROL (2014)

Article Engineering, Biomedical

Remote Detection of Photoplethysmographic Systolic and Diastolic Peaks Using a Digital Camera

Daniel McDuff et al.

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING (2014)

Article Engineering, Biomedical

Noncontact Monitoring Breathing Pattern, Exhalation Flow Rate and Pulse Transit Time

Dangdang Shao et al.

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING (2014)

Article Biophysics

Non-contact video-based vital sign monitoring using ambient light and auto-regressive models

L. Tarassenko et al.

PHYSIOLOGICAL MEASUREMENT (2014)

Article Engineering, Biomedical

Robust Pulse Rate From Chrominance-Based rPPG

Gerard de Haan et al.

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING (2013)

Article Multidisciplinary Sciences

Remote Measurements of Heart and Respiration Rates for Telemedicine

Fang Zhao et al.

PLOS ONE (2013)

Article Computer Science, Software Engineering

Eulerian Video Magnification for Revealing Subtle Changes in the World

Hao-Yu Wu et al.

ACM TRANSACTIONS ON GRAPHICS (2012)

Review Peripheral Vascular Disease

Assessment of collateral circulation to the hand prior to radial artery harvest

Joseph Habib et al.

VASCULAR MEDICINE (2012)

Article Mathematical & Computational Biology

Measuring Pulse Rate with a Webcam

Magdalena Lewandowska et al.

JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS (2012)

Article Engineering, Biomedical

Advancements in Noncontact, Multiparameter Physiological Measurements Using a Webcam

Ming-Zher Poh et al.

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING (2011)

Article Biochemical Research Methods

Motion-compensated noncontact imaging photoplethysmography to monitor cardiorespiratory status during exercise

Yu Sun et al.

JOURNAL OF BIOMEDICAL OPTICS (2011)

Article Statistics & Probability

Principal component analysis

Herve Abdi et al.

WILEY INTERDISCIPLINARY REVIEWS-COMPUTATIONAL STATISTICS (2010)

Article Engineering, Biomedical

Optical vibrocardiography: A novel tool for the optical monitoring of cardiac activity

Umberto Morbiducci et al.

ANNALS OF BIOMEDICAL ENGINEERING (2007)

Review Pediatrics

Scoliosis and the respiratory system

Anastassios C. Koumbourlis

PAEDIATRIC RESPIRATORY REVIEWS (2006)

Article Obstetrics & Gynecology

Short term heart rate variability in healthy neonates:: Normative data and physiological observations

E Longin et al.

EARLY HUMAN DEVELOPMENT (2005)

Review Neurosciences

Modulatory effects of respiration

L Bernardi et al.

AUTONOMIC NEUROSCIENCE-BASIC & CLINICAL (2001)

Article Physiology

Assessing thoracoabdominal asynchrony

AMS Black et al.

CLINICAL PHYSIOLOGY (2001)

Article Computer Science, Artificial Intelligence

A flexible new technique for camera calibration

ZY Zhang

IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE (2000)