4.6 Article

Continuous 24-h Photoplethysmogram Monitoring Enables Detection of Atrial Fibrillation

Journal

FRONTIERS IN PHYSIOLOGY
Volume 12, Issue -, Pages -

Publisher

FRONTIERS MEDIA SA
DOI: 10.3389/fphys.2021.778775

Keywords

atrial fibrillation; photoplethysmography; photoplethysmogram; quality; algorithms; monitoring; screening; signal quality analysis

Categories

Ask authors/readers for more resources

A study evaluated the feasibility of continuous photoplethysmogram (PPG) for atrial fibrillation (AF) detection. The results showed that continuous PPG can provide reliable AF identification during both daytime and nighttime, with better PPG data quality at night. Users had a positive experience with the device.
Aim: Atrial fibrillation (AF) detection is challenging because it is often asymptomatic and paroxysmal. We evaluated continuous photoplethysmogram (PPG) for signal quality and detection of AF.Methods: PPGs were recorded using a wrist-band device in 173 patients (76 AF, 97 sinus rhythm, SR) for 24 h. Simultaneously recorded 3-lead ambulatory ECG served as control. The recordings were split into 10-, 20-, 30-, and 60-min time-frames. The sensitivity, specificity, and F1-score of AF detection were evaluated for each time-frame. AF alarms were generated to simulate continuous AF monitoring. Sensitivities, specificities, and positive predictive values (PPVs) of the alarms were evaluated. User experiences of PPG and ECG recordings were assessed. The study was registered in the Clinical Trials database (NCT03507335).Results: The quality of PPG signal was better during night-time than in daytime (67.3 +/- 22.4% vs. 30.5 +/- 19.4%, p < 0.001). The 30-min time-frame yielded the highest F1-score (0.9536), identifying AF correctly in 72/76 AF patients (sensitivity 94.7%), only 3/97 SR patients receiving a false AF diagnosis (specificity 96.9%). The sensitivity and PPV of the simulated AF alarms were 78.2 and 97.2% at night, and 49.3 and 97.0% during the daytime. 82% of patients were willing to use the device at home.Conclusion: PPG wrist-band provided reliable AF identification both during daytime and night-time. The PPG data's quality was better at night. The positive user experience suggests that wearable PPG devices could be feasible for continuous rhythm monitoring.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available