4.6 Article

Sensory Percepts Elicited by Chronic Macro-Sieve Electrode Stimulation of the Rat Sciatic Nerve

Journal

FRONTIERS IN NEUROSCIENCE
Volume 15, Issue -, Pages -

Publisher

FRONTIERS MEDIA SA
DOI: 10.3389/fnins.2021.758427

Keywords

peripheral nerve stimulation; macro-sieve electrode; regenerative electrode; sensory feedback; sensorimotor restoration; nerve regeneration; rat behavior; sciatic nerve

Categories

Funding

  1. Pilot Project

Ask authors/readers for more resources

The study investigated the viability of the MSE as a sensory feedback interface through a rat sciatic nerve and behavioral model, finding that the MSE can elicit sensory percepts at low current levels and laying the groundwork for future experiments to study other devices, stimulus parameters, and task paradigms.
Objective: Intuitive control of conventional prostheses is hampered by their inability to provide the real-time tactile and proprioceptive feedback of natural sensory pathways. The macro-sieve electrode (MSE) is a candidate interface to amputees' truncated peripheral nerves for introducing sensory feedback from external sensors to facilitate prosthetic control. Its unique geometry enables selective control of the complete nerve cross-section by current steering. Unlike previously studied interfaces that target intact nerve, the MSE's implantation requires transection and subsequent regeneration of the target nerve. Therefore, a key determinant of the MSE's suitability for this task is whether it can elicit sensory percepts at low current levels in the face of altered morphology and caliber distribution inherent to axon regeneration. The present in vivo study describes a combined rat sciatic nerve and behavioral model developed to answer this question. Approach: Rats learned a go/no-go detection task using auditory stimuli and then underwent surgery to implant the MSE in the sciatic nerve. After healing, they were trained with monopolar electrical stimuli with one multi-channel and eight single-channel stimulus configurations. Psychometric curves derived by the method of constant stimuli (MCS) were used to calculate 50% detection thresholds and associated psychometric slopes. Thresholds and slopes were calculated at two time points 3 weeks apart. Main Results: For the multi-channel stimulus configuration, the average current required for stimulus detection was 19.37 mu A (3.87 nC) per channel. Single-channel thresholds for leads located near the nerve's center were, on average, half those of leads located near the periphery (54.92 mu A vs. 110.71 mu A, or 10.98 nC vs. 22.14 nC). Longitudinally, 3 of 5 leads' thresholds decreased or remained stable over the 3-week span. The remaining two leads' thresholds increased by 70-74%, possibly due to scarring or device failure. Significance: This work represents an important first step in establishing the MSE's viability as a sensory feedback interface. It further lays the groundwork for future experiments that will extend this model to the study of other devices, stimulus parameters, and task paradigms.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available