4.6 Article

Delay-Spectral Focusing Dual-Comb Coherent Raman Spectroscopy for Rapid Detection in the High-Wavenumber Region

Journal

ACS PHOTONICS
Volume 9, Issue 4, Pages 1385-1394

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/acsphotonics.2c00136

Keywords

coherent Raman spectroscopy; dual-comb spectroscopy; optical frequency comb; electro-optic modulation; microfluidics

Funding

  1. National Natural Science Foundation of China [61775114, 62174096]

Ask authors/readers for more resources

A novel delay-spectral focusing dual-comb CARS scheme is proposed in this study for rapid HW Raman detection. By combining the advantages of DC asynchronous optical sampling and spectral focusing, the Raman spectrum is directly mapped to DC relative delay, releasing the coherence constraint of excitation sources. Rapid acquisition rate tuning and high-throughput measurement in the HW region are achieved with stable spectral resolution and signal-to-noise ratio.
Rapid multiplex coherent anti-Stokes Raman scattering (CARS) spectroscopy in the high-wavenumber (HW) region shows great advantages in real-time dynamic process visualizations, clinical diagnosis, abundant microplastic assessment, etc. Fourier transform CARS (FT-CARS) improves the acquisition speed of multiplex CARS to the order of tens of kHz, yet typical approaches to utilize the intrinsic coherence of ultrabroadband pulses notably impede the attainable Raman vibrations in the HW region. Here, a novel delay-spectral focusing dual-comb (DC) CARS scheme is proposed for rapid HW Raman detection based on two fiber combs with 100 MHz repetition rates. By combining the particular advantages of DC asynchronous optical sampling and spectral focusing instantaneous single molecular vibration excitation, the Raman spectrum directly maps to DC relative delay, releasing the coherence constraint of excitation sources. Thus, an Er comb and a Yb comb, as pump and Stokes excitation pulses, respectively, flexibly match the Raman vibration in the HW region. Further, a rapid delay focusing method with intracavity electro-optic modulation is applied to actively control the DC relative delay scanning in the Raman shift region of interest. With these efforts, the spectral acquisition rate is improved more than 1000-fold up to 40 000 spectra/s, while keeping spectral resolution (similar to 10 cm(-1)) and the signal-to-noise ratio (similar to 260) stable along with active acquisition rate tuning. Combined with a microfluidic device, high-speed measurement in the HW region of 15 mu m microbeads in flow is demonstrated by the system, reaching a high throughput of around 2150 events/s and more than 99% classification consistency. The prospect of rapid acquiring multiplex CARS spectra without the sacrifice of spectral resolution or the need for the coherence of the pulse sources offers huge potential in rapid monitoring circumstances, such as flow cytometry and microspectroscopic imaging in biomedicine.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available