4.6 Article

Coronary Endothelium-Dependent Vasomotor Function After Drug-Eluting Stent and Bioresorbable Scaffold Implantation

Journal

JOURNAL OF THE AMERICAN HEART ASSOCIATION
Volume 10, Issue 22, Pages -

Publisher

WILEY
DOI: 10.1161/JAHA.121.022123

Keywords

drug-eluting stents; endothelial dysfunction; optical coherence tomography; ST-segment-elevation myocardial infarction

Funding

  1. La Marato Foundation
  2. Spanish Heart Foundation
  3. OrbusNeich

Ask authors/readers for more resources

This study investigated the impact of different stents on endothelial function, finding variations in vasomotor responses and neointimal healing between devices, but no significant differences in endothelial dysfunction issues.
Background Early generation drug-eluting stents (DESs) showed a high grade of coronary endothelial dysfunction that was attributed to lack of stent reendothelialization. Endothelium-dependent vasomotor response of current DESs and bioresorbable scaffolds (BRSs) remains unknown. This study sought to assess the device-related endothelial function of current devices and to correlate neointima healing with endothelial function. Methods and Results A total of 206 patients from 4 randomized trials treated with the durable-polymer everolimus-eluting Xience (n=44), bioresorbable-polymer sirolimus-eluting Orsiro (n=35), polymer-free biolimus-eluting Biofreedom (n=24), bioactive endothelial-progenitor cell-capturing sirolimus-eluting Combo DES (n=25), polymer-based everolimus-eluting Absorb (n=44), and Mg-based sirolimus-eluting Magmaris BRS (n=34) underwent endothelium-dependent vasomotor tests and optical coherence tomography imaging, as per protocol, at follow-up. Crude vasomotor responses of distal segments to low-dose acetylcholine (10(-6) mol/L) were different between groups: bioresorbablepolymer DEShad the worst (-8.4%+/- 12.6%) and durable-polymer DES had the most physiologic (-0.4%+/- 11.8%; P=0.014). High-dose acetylcholine (10(-4) mol/L) showed similar responses between groups (ranging from -10.8%+/- 11.6% to -18.1%+/- 15.4%; P=0.229). Device healing was different between devices. Uncovered struts ranged from 6.3%+/- 7.1% (bioresorbable-polymer DES) to 2.5%+/- 4.5% (bioactive DES; P=0.056). In multivariate models, endothelium-dependent vasomotor response was associated with age, bioresorbable-polymer DES, and angiographic lumen loss, but not with strut coverage nor plaque type. Endothelial dysfunction (defined as >= 4% vasoconstriction) was observed in 46.6% of patients with low-dose and 68.9% with high-dose acetylcholine, without differences between groups. Conclusions At follow-up, endothelial dysfunction was frequently observed in distal segments treated with current stents without remarkable differences between devices. Although neointima healing was different between devices, poor healing was not associated with endothelial dysfunction.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available