4.5 Article Proceedings Paper

Operating Temperatures and Diurnal Temperature Variations of Modules Installed in Open-Rack and Typical BIPV Configurations

Journal

IEEE JOURNAL OF PHOTOVOLTAICS
Volume 12, Issue 1, Pages 133-140

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JPHOTOV.2021.3114988

Keywords

Building-integrated photovoltaics (BIPV); diurnal (day-night) temperature variation; IEC TS 63126; module temperature; T-98

Funding

  1. Swiss National Science Foundation [COST IZCOZ0_182967/1]

Ask authors/readers for more resources

Due to restricted rear-side ventilation, building-integrated photovoltaics (BIPV) modules and systems tend to have elevated operating temperatures. A study conducted in Southern Switzerland found that BIPV modules operated at significantly higher temperatures and experienced greater day-night temperature variations compared to modules in an open-rack configuration.
Because of building skin integration with restricted or reduced rear-side ventilation, elevated operating temperatures are expected in building-integrated photovoltaics (BIPV) modules and systems, which may impact their long performance and reliability. This article reports an analysis of operating temperatures and diurnal (day-night) temperature variations of the modules in open-rack and some BIPV mounting configurations (BIPV-ventilated and BIPV-insulated) monitored over a period of 2-5 years in Southern Switzerland. The modules in BIPV configurations operated at 20 degrees C-30 degrees C higher temperatures than the same modules installed in an open-rack configuration. In the worst-case, the temperature of the BIPV modules reached values slightly above 90 degrees C. In addition, the modules installed in BIPV configurations were confronted with considerably greater diurnal (day-night) temperature variations compared with the same modules with an open-rack mounting (on average 18 degrees C-25 degrees C more). This demonstrates that these modules can suffer from higher thermo-mechanical stresses, potentially leading to accelerated degradation rates, and shorter lifetimes. The suitability of the indoor qualification and safety tests in IEC 61215 and IEC 61730 were evaluated according to the threshold set at the 98th percentile real-life operating module temperature (as defined in the IEC TS 63126 guideline for qualifying PV modules operating at elevated temperatures). This study shows that according to IEC TS 63126, BIPV modules on a tilted surface in Southern Switzerland may need to be tested at harsher environmental conditions (e.g., higher temperatures) in a selection of indoor qualification and safety tests.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available