Ask authors/readers for more resources

In patients undergoing total ankle arthroplasty, skin adhesive showed better patient satisfaction for wound cosmesis compared to interrupted polypropylene sutures, but had significantly higher rates of wound complications.
Background Adhesive skin materials have increasingly been used in orthopedic surgery. We aimed to compare the efficacy and safety of skin adhesive (2-octyl cyanoacrylate and polymer mesh, Dermabond Prineo) and interrupted polypropylene sutures for wound closure in patients undergoing total ankle arthroplasty (TAA). Methods We prospectively enrolled 107 consecutive patients (108 ankles) undergoing TAA and divided them into two groups: skin adhesive group (36 ankles) and suture group (72 ankles). The primary outcome assessment included wound complications and patient satisfaction for wound cosmesis. The secondary outcome assessment included duration of surgery, length of hospital stay, and the Ankle Osteoarthritis Scale (AOS) pain and disability score. Results There was one case of allergic contact dermatitis, three cases of wound dehiscence, and one case of superficial surgical site infection in the skin adhesive group. Among them, one case each with allergic contact dermatitis and wound dehiscence finally progressed to deep surgical site infection. Three cases of wound dehiscence were also reported in the suture group; however, there was no case of surgical site infection. Patient satisfaction for wound cosmesis was significantly higher in the skin adhesive group than in the suture group (p = 0.001). There was no statistically significant difference between the groups in terms of secondary outcomes (p > 0.05). Conclusions Although the use of Dermabond Prineo showed better patient satisfaction for wound cosmesis, it showed significantly high wound complication rates and no other clinical benefits compared to interrupted polypropylene suture in TAA. Our results suggest that awareness of the possibility of wound complications is necessary when Dermabond Prineo is used in TAA.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available