4.5 Review

Anatomical and physiological considerations in scleral lens wear: Intraocular pressure

Related references

Note: Only part of the references are listed.
Article Ophthalmology

Bruch Membrane Opening Minimum Rim Width Changes During Scleral Lens Wear

Dan Samaha et al.

Summary: This study found that scleral lens wear significantly decreases BMO-MRW, which may be attributed to changes in intraocular pressure, and is not affected by corneal rigidity, central corneal thickness, or refractive error. Further research is needed to better understand the significance of these changes at the optic nerve head during scleral lens wear.

EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE (2021)

Article Health Care Sciences & Services

Effects of Scleral Contact Lenses for Keratoconus Management on Visual Quality and Intraocular Pressure

Martina Formisano et al.

Summary: The study found that scleral contact lenses significantly improved visual acuity in patients with keratoconus, potentially leading to a small increase in intraocular pressure, which may not have a significant impact on otherwise healthy eyes.

THERAPEUTICS AND CLINICAL RISK MANAGEMENT (2021)

Article Ophthalmology

Comparison of Tono-Pen Avia and Handheld Applanation Tonometry in Primary Congenital Glaucoma

Sebastiao Cronemberger et al.

Summary: The study compared intraocular pressure measurements obtained using Tono-Pen AVIA (TPA) and handheld Goldmann applanation tonometer (GAT) in children with primary congenital glaucoma (PCG), finding a significant difference between the two devices. The difference in IOP values between TPA and GAT in PCG was influenced by central corneal thickness, age, and GAT IOP values.

JOURNAL OF GLAUCOMA (2021)

Article Ophthalmology

Real-world comparison between the Tonopen and Goldmann applanation tonometry in a university glaucoma clinic

Max J. Blumberg et al.

Summary: Tonopen and GAT intraocular pressure measurements were found to be similar and directly correlated in 300 consecutive patients. However, GAT measurements were significantly higher than Tonopen in patients with bilateral primary open-angle glaucoma. Further research is needed to assess the limitations of Tonopen IOP measurements in eyes with different GAT IOP levels.

INTERNATIONAL OPHTHALMOLOGY (2021)

Article Ophthalmology

Agreement of Corrected Intraocular Pressure Values Between Corvis ST and Pentacam in Patients With Keratoconus, Subclinical Keratoconus, and Normal Cornea

Yanhui Chen et al.

Summary: This study found that in patients with keratoconus, there was poor agreement of corrected intraocular pressure values between Pentacam and Corvis ST; whereas in the subclinical KC and control groups, the corrected IOP values derived from the two devices were similar. Corneal biomechanical parameters may affect the differences between Delta IOP1 and Delta IOP2.

CORNEA (2021)

Article Ophthalmology

Reliability of iCare ic100 Rebound Tonometry and Agreement With Goldmann Applanation Tonometry in Healthy and Post-myopic LASIK Patients

Alicia Gomez-Gomez et al.

Summary: Rebound tonometry shows good or excellent clinical reliability for obtaining intraocular pressure measurements in healthy individuals and post-myopic LASIK patients, regardless of corneal parameters and axial length, making it a reliable tool for the management of glaucoma in these populations.

JOURNAL OF GLAUCOMA (2021)

Article Medicine, General & Internal

Glaucoma

Jessica Minjy Kang et al.

MEDICAL CLINICS OF NORTH AMERICA (2021)

Article Ophthalmology

CLEAR-Scleral lenses

Melissa Barnett et al.

Summary: The report provides a historical review and detailed account of the contemporary use of scleral lenses, highlighting them as the optimal choice for contact lens wear across various clinical indications and potentially delaying the need for corneal surgery. It also discusses the challenges and future applications associated with modern scleral lens fitting and evaluation processes.

CONTACT LENS & ANTERIOR EYE (2021)

Article Multidisciplinary Sciences

Alteration of corneal biomechanical properties in patients with dry eye disease

Vannarut Satitpitakul et al.

Summary: This study evaluated the association between symptoms and signs of dry eye diseases (DED) with corneal biomechanical parameters, finding that as the severity of DED increased, corneal biomechanics worsened, but there was no significant difference in tear production levels.

PLOS ONE (2021)

Article Ophthalmology

Agreement of Intraocular Pressure Measurement of Icare ic200 with Goldmann Applanation Tonometer in Adult Eyes with Normal Cornea

Swathi Vallabh Badakere et al.

Summary: The study compared the agreement between Icare ic200 and Goldmann Applanation Tonometer in measuring intraocular pressure in adult eyes, showing good consistency in measurement across different IOP ranges, but with a tendency for Icare ic200 to overestimate IOP, especially as IOP increases.

OPHTHALMOLOGY GLAUCOMA (2021)

Article Ophthalmology

Effect of Scleral Lens Wear on Central Corneal Thickness and Intraocular Pressure in Patients With Ocular Surface Disease

Kevin C. Shahnazi et al.

EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE (2020)

Article Ophthalmology

The impact of short-term fenestrated scleral lens wear on intraocular pressure

Samuel Y. Cheung et al.

CONTACT LENS & ANTERIOR EYE (2020)

Article Ophthalmology

In vivomeasures of anterior scleral resistance in humans with rebound tonometry

Hetal D. Buckhurst et al.

OPHTHALMIC AND PHYSIOLOGICAL OPTICS (2020)

Review Ophthalmology

Anatomical and physiological considerations in scleral lens wear: Conjunctiva and sclera

Maria K. Walker et al.

CONTACT LENS & ANTERIOR EYE (2020)

Article Ophthalmology

Intraocular pressure changes in neophyte scleral lens wearers: A prospective study

Elise G. Kramer et al.

CONTACT LENS & ANTERIOR EYE (2020)

Review Ophthalmology

Fenestrated Scleral Lenses: Back to the Origins? Review of Their Benefits and Fitting Techniques

Daddi Fadel et al.

OPTOMETRY AND VISION SCIENCE (2020)

Article Ophthalmology

Changes in Scleral Tonometry and Anterior Chamber Angle after Short-term Scleral Lens Wear

Chukwuemeka Junior Obinwanne et al.

OPTOMETRY AND VISION SCIENCE (2020)

Article Ophthalmology

IOP and Optic Nerve Head Morphology during Scleral Lens Wear

Maria K. Walker et al.

OPTOMETRY AND VISION SCIENCE (2020)

Article Ophthalmology

The time course and nature of corneal oedema during sealed miniscleral contact lens wear

Stephen J. Vincent et al.

CONTACT LENS & ANTERIOR EYE (2019)

Article Ophthalmology

Anterior eye surface changes following miniscleral contact lens wear

Alejandra Consejo et al.

CONTACT LENS & ANTERIOR EYE (2019)

Article Ophthalmology

Reproducibility of minimum rim width and retinal nerve fibre layer thickness using the Anatomic Positioning System in glaucoma patients

Lalita Gupta et al.

CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE (2019)

Article Ophthalmology

Impact of Corneoscleral Contact Lens Usage on Corneal Biomechanical Parameters in Keratoconic Eyes

Esteban Porcar et al.

EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE (2019)

Review Ophthalmology

Potential contraindications to scleral lens wear

Daddi Fadel et al.

CONTACT LENS & ANTERIOR EYE (2019)

Article Ophthalmology

The treatment of ocular hypotony after trabeculectomy with a scleral lens: A case series

K. H. Elving-Kokke et al.

CONTACT LENS & ANTERIOR EYE (2019)

Article Ophthalmology

Intra-ocular pressure variation associated with the wear of scleral lenses of different diameters

Langis Michaud et al.

CONTACT LENS & ANTERIOR EYE (2019)

Article Ophthalmology

Reproducibility of 5 Methods of Ocular Tonometry

Anne E. Kutzscher et al.

OPHTHALMOLOGY GLAUCOMA (2019)

Article Ophthalmology

Region-Specific Changes in Postlens Fluid Reservoir Depth Beneath Small-Diameter Scleral Lenses Over 2 Hours

Cherie B. Nau et al.

EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE (2018)

Article Ophthalmology

Corneal Biomechanical Parameters With Corneoscleral Contact Lenses in Post-Laser In Situ Keratomileusis Eyes

Juan C. Montalt et al.

EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE (2018)

Article Ophthalmology

The effects of graded intraocular pressure challenge on the optic nerve head

Nimesh Patel et al.

EXPERIMENTAL EYE RESEARCH (2018)

Article Ophthalmology

Correlation of Corneal and Scleral Pneumatonometry in Pediatric Patients

Jun Hui Lee et al.

OPHTHALMOLOGY (2018)

Article Ophthalmology

The temporal dynamics of miniscleral contact lenses: Central corneal clearance and centration

Stephen J. Vincent et al.

CONTACT LENS & ANTERIOR EYE (2018)

Article Ophthalmology

Quantification of Pulse-Dependent Trabecular Meshwork Motion in Normal Humans Using Phase-Sensitive OCT

Chen Xin et al.

INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE (2018)

Editorial Material Ophthalmology

Evidence on scleral contact lenses and intraocular pressure

Stephen J. Vincent et al.

CLINICAL AND EXPERIMENTAL OPTOMETRY (2017)

Article Ophthalmology

Aqueous outflow - A continuum from trabecular meshwork to episcleral veins

Teresia Carreon et al.

PROGRESS IN RETINAL AND EYE RESEARCH (2017)

Article Ophthalmology

Intraday Repeatability of Bruch's Membrane Opening-Based Neuroretinal Rim Measurements

Philip Enders et al.

INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE (2017)

Editorial Material Ophthalmology

A hypothesis that scleral contact lenses could elevate intraocular pressure

Charles W. Mcmonnies

CLINICAL AND EXPERIMENTAL OPTOMETRY (2016)

Article Ophthalmology

Intraocular Pressure After 2 Hours of Small-Diameter Scleral Lens Wear

Cherie B. Nau et al.

EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE (2016)

Article Ophthalmology

Diurnal variation of anterior scleral and conjunctival thickness

Scott A. Read et al.

OPHTHALMIC AND PHYSIOLOGICAL OPTICS (2016)

Article Multidisciplinary Sciences

Anterior eye tissue morphology: Scleral and conjunctival thickness in children and young adults

Scott A. Read et al.

SCIENTIFIC REPORTS (2016)

Article Ophthalmology

Anatomical Variation of Human Collector Channel Orifices

Michael D. Bentley et al.

INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE (2016)

Article Ophthalmology

Modern disposable hydrogel contact lens removal has a minimal effect on intraocular pressure

Kirsten Hamilton-Maxwell et al.

OPHTHALMIC AND PHYSIOLOGICAL OPTICS (2015)

Article Ophthalmology

Correlation of Serial Scleral and Corneal Pneumatonometry

Debbie S. Kuo et al.

OPHTHALMOLOGY (2015)

Article Ophthalmology

Aqueous Humor Outflow: Dynamics and Disease

Uttio Roy Chowdhury et al.

INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE (2015)

Review Ophthalmology

Intraocular Pressure Homeostasis: Maintaining Balance in a High-Pressure Environment

Ted S. Acott et al.

JOURNAL OF OCULAR PHARMACOLOGY AND THERAPEUTICS (2014)

Article Ophthalmology

A Comparison of the Short-Term Settling of Three Scleral Lens Designs

Matthew J. Kauffman et al.

OPTOMETRY AND VISION SCIENCE (2014)

Article Ophthalmology

Correlation Between Corneal and Sclera! Pneumatonometry: An Alternative Method for Intraocular Pressure Measurement

Michael A. Kapamajian et al.

AMERICAN JOURNAL OF OPHTHALMOLOGY (2013)

Article Ophthalmology

Diaton tonometry: an assessment of validity and preference against Goldmann tonometry

Mark D. Doherty et al.

CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY (2012)

Review Ophthalmology

Systematic Review of the Agreement of Tonometers with Goldmann Applanation Tonometry

Jonathan Alistair Cook et al.

OPHTHALMOLOGY (2012)

Review Ophthalmology

Pulsatile flow into the aqueous veins: Manifestations in normal and glaucomatous eyes

Murray Johnstone et al.

EXPERIMENTAL EYE RESEARCH (2011)

Article Ophthalmology

Transpalpebral measurement of intraocular pressure using the Diaton tonometer versus standard Goldmann applanation tonometry

Yuehua Li et al.

GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY (2010)

Review Ophthalmology

Aqueous Humor Dynamics in Historical Perspective

Harry H. Mark

SURVEY OF OPHTHALMOLOGY (2010)

Article Ophthalmology

INCREASE OF THE INTRAOCULAR PRESSURE WHEN USING CONTACT GLASSES

A. Huggert

ACTA OPHTHALMOLOGICA (2009)

Review Ophthalmology

Incorporating corneal pachymetry into the management of glaucoma

Michele Iester et al.

JOURNAL OF CATARACT AND REFRACTIVE SURGERY (2009)

Review Ophthalmology

Extracellular matrix in the trabecular meshwork

Ted S. Acott et al.

EXPERIMENTAL EYE RESEARCH (2008)

Article Ophthalmology

Technical Note:: A comparison of central and peripheral intraocular pressure using rebound tonometry

A. Queiros et al.

OPHTHALMIC AND PHYSIOLOGICAL OPTICS (2007)

Article Ophthalmology

Aqueous humor outflow: What do we know? Where will it lead us?

Michael P. Fautsch et al.

INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE (2006)

Article Ophthalmology

Deviations between transpalpebral tonometry using TGDc-01 and Goldmann applanation tonometry depending on the IOP level

A Troost et al.

GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY (2005)

Article Ophthalmology

Changes in gene expression by trabecular meshwork cells in response to mechanical stretching

V Vittal et al.

INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE (2005)

Review Developmental Biology

Anterior segment development relevant to glaucoma

DB Gould et al.

INTERNATIONAL JOURNAL OF DEVELOPMENTAL BIOLOGY (2004)

Article Ophthalmology

Relationship between ciliary blood flow and aqueous production rabbits

HA Reitsamer et al.

INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE (2003)

Article Ophthalmology

Effects of scleral search coil wear on visual function

EL Irving et al.

INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE (2003)

Article Ophthalmology

The effect of scleral search coil lens wear on the eye

PJ Murphy et al.

BRITISH JOURNAL OF OPHTHALMOLOGY (2001)