4.7 Article

Comparison of bacterial filtration efficiency vs. particle filtration efficiency to assess the performance of non-medical face masks

Journal

SCIENTIFIC REPORTS
Volume 12, Issue 1, Pages -

Publisher

NATURE PORTFOLIO
DOI: 10.1038/s41598-022-05245-4

Keywords

-

Funding

  1. Saint-Etienne Metropole, IMT (Institut Mines-Telecom)
  2. Fondation de France
  3. French National Research Agency as part of the Research-Action on COVID-19 program (contract ANR RA-COVID named FAMAS)

Ask authors/readers for more resources

This study compared the BFE results of medical facemasks with the PFE results from non-medical facemasks, finding a correlation between the two. It was observed that PFE values were higher than BFE values due to differences in particle size distribution considered for efficiency calculation. To properly compare these test protocols for better deduction, it would be interesting to compare filtration efficiency for a similar granulometric range.
As a result of the current COVID-19 pandemic, the use of facemasks has become commonplace. The performance of medical facemasks is assessed using Bacterial Filtration Efficiency (BFE) tests. However, as BFE tests, require specific expertise and equipment and are time-consuming, the performance of non-medical facemasks is assessed with non-biological Particle Filtration Efficiency (PFE) tests which are comparatively easier to implement. It is necessary to better understand the possible correlations between BFE and PFE to be able to compare the performances of the different types of masks (medical vs. non-medical). In this study BFE results obtained in accordance with the standard EN 14683 are compared to the results of PFE from a reference test protocol defined by AFNOR SPEC S76-001 with the aim to determine if BFE could be predicted from PFE. Our results showed a correlation between PFE and BFE. It was also observed that PFE values were higher than BFE and this was attributed to the difference in particle size distribution considered for efficiency calculation. In order to properly compare these test protocols for a better deduction, it would be interesting to compare the filtration efficiency for a similar granulometric range.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available