4.6 Article

On the Corrosion Fatigue of Magnesium Alloys Aimed at Biomedical Applications: New Insights from the Influence of Testing Frequency and Surface Modification of the Alloy ZK60

Journal

MATERIALS
Volume 15, Issue 2, Pages -

Publisher

MDPI
DOI: 10.3390/ma15020567

Keywords

magnesium alloys; fatigue; corrosion; corrosion fatigue; coatings; frequency; stress corrosion cracking

Ask authors/readers for more resources

Magnesium alloys, especially in medical applications, face challenges due to their poor resistance to environmentally assisted fracture and bio-corrosion degradation. This study focuses on the corrosion fatigue behavior of a popular Mg-Zn-Zr alloy, specifically examining the effects of testing frequency, surface roughness, and metallic coatings. The results demonstrate that the occurrence of corrosion fatigue in Mg alloys is influenced by multiple factors, showing a complicated interplay between corrosion damage, stress corrosion cracking, and cyclic loads.
Magnesium alloys are contemporary candidates for many structural applications of which medical applications, such as bioresorbable implants, are of significant interest to the community and a challenge to materials scientists. The generally poor resistance of magnesium alloys to environmentally assisted fracture, resulting, in particular, in faster-than-desired bio-corrosion degradation in body fluids, strongly impedes their broad uptake in clinical practice. Since temporary structures implanted to support osteosynthesis or healing tissues may experience variable loading, the resistance to bio-corrosion fatigue is a critical issue that has yet to be understood in order to maintain the structural integrity and to prevent the premature failure of implants. In the present communication, we address several aspects of the corrosion fatigue behaviour of magnesium alloys, using the popular commercial ZK60 Mg-Zn-Zr alloy as a representative example. Specifically, the effects of the testing frequency, surface roughness and metallic coatings are discussed in conjunction with the fatigue fractography after the testing of miniature specimens in air and simulated body fluid. It is demonstrated that accelerated environmentally assisted degradation under cyclic loading occurs due to a complicated interplay between corrosion damage, stress corrosion cracking and cyclic loads. The occurrence of corrosion fatigue in Mg alloys is exaggerated by the significant sensitivity to the testing frequency. The fatigue life or strength reduced remarkably with a decrease in the test frequency.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available