CAD-CAM Fabricated Denture Base Resins: In Vitro Investigation of the Minimum Acceptable Denture Base Thickness

Publisher

WILEY
DOI: 10.1111/jopr.13486

Keywords

CAD-CAM; digital dentistry; flexural properties; denture base thickness; PMMA

Ask authors/readers for more resources

This study investigated the influence of reducing material thickness on the flexural properties of CAD-CAM denture base resins. The results showed that reducing the thickness of materials made via the subtractive method did not significantly affect flexural strength, while it did have an impact on materials made via the additive method. Within certain thickness ranges, these materials still exhibited clinically acceptable flexural properties.
Purpose To investigate the influence of reducing material thickness on flexural properties of computer-aided design and computer-aided manufacturing (CAD-CAM) denture base resins. Materials and methods Four CAD-CAM denture base acrylic resin materials were selected; two were made via the subtractive method (AvaDent and IvoCad) and two were made with the additive method (FormLabs and NextDent). One heat-polymerized denture base material was used as a control. Specimens were fabricated with varying thicknesses (n = 10/group): 3.3 mm, 2.5 mm, 2 mm, or 1.5 mm. Flexural strength was evaluated via a three-point bending test. One- and two-way ANOVA were used for data analysis along with Tukey's post hoc comparison (alpha = 0.05). Results Reducing the thickness of materials made via the subtractive method did not influence flexural strength up to 2 mm (p > 0.05). However, the difference was significant at a 1.5 mm thickness (p < 0.001). For materials made via the additive method, NextDent specimens had no significant decrease in flexural strength when the thickness was reduced to 2 mm (p = 0.58). FormLabs specimens showed a significant decrease (p < 0.001), although the values of flexural strength were clinically acceptable. During testing, specimens manufactured via the additive method at a 1.5 mm thickness bent without fracturing and were therefore excluded. All materials showed a reduction in elastic modulus as the thickness decreased (p < 0.001). Conclusion Heat-polymerized, AvaDent, and IvoCad materials may be used for denture base fabrication at a minimum thickness of 1.5 mm. FormLabs and NextDent may be fabricated at a 2 mm minimum thickness, with clinically acceptable flexural properties.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available