4.6 Article

Numerical studies on issues of Re-independence for indoor airflow and pollutant dispersion within an isolated building

Journal

BUILDING SIMULATION
Volume 15, Issue 7, Pages 1259-1276

Publisher

TSINGHUA UNIV PRESS
DOI: 10.1007/s12273-021-0846-z

Keywords

CFD simulation; Re-independence; similarity criterion; indoor ventilation; pollutant dispersion

Funding

  1. Shanghai Sailing Program [18YF1417600]
  2. Scientific and Innovative Action Plan of Shanghai [20dz1204008]
  3. National Natural Science Foundation of China [51536006]

Ask authors/readers for more resources

This study investigated the Re-independence of indoor airflow and pollutant dispersion within an isolated building using numerical models validated by wind-tunnel experiments. The critical Reynolds number for indoor flow and turbulent diffusion was found to be position-dependent and should be suggested as the optimal value at the most unfavorable position. The study recommends different critical Reynolds numbers for outdoor and indoor flows, and emphasizes that indoor pollutant diffusion is completely determined by flow structures.
This study conducted the numerical models validated by wind-tunnel experiments to investigate the issues of Re-independence of indoor airflow and pollutant dispersion within an isolated building. The window Reynolds number (Re-w) was specified to characterize the indoor flow and dispersion. The indicators of RRC (ratio of relative change) or DR (K_DR) (difference ratio of dimensionless concentration) <= 5% were applied to quantitatively determine the critical Re-w for indoor flow and turbulent diffusion. The results show that the critical Re (Re-crit) value is position-dependent, and Re-crit at the most unfavorable position should be suggested as the optimal value within the whole areas of interest. Thus Re-H,Re-crit = 27,000 is recommended for the outdoor flows; while Re-w,Re-crit = 15,000 is determined for the indoor flows due to the lower part below the window showing the most unfavorable. The suggested Re-w,Re-crit (=15,000) for indoor airflow and cross ventilation is independence of the window size. Moreover, taking K_DR <= 5% as the indicator, the suggested Re-w,Re-crit for ensuring indoor pollutant diffusion enter the Re-independence regime should also be 15,000, indicating that indoor passive diffusion is completely determined by the flow structures. The contours of dimensionless velocity (U/U-0) and concentration (K) against the increasing Re-w further confirmed this critical value. This study further reveals the Re-independence issues for indoor flow and dispersion to ensure the reliability of the data obtained by reduced-scale numerical or wind-tunnel models.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available