4.7 Article

A derivatization and microextraction procedure with organic phase solidification on a paper template: Spectrofluorometric determination of formaldehyde in milk

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.saa.2021.120160

Keywords

Derivatization; Fluorescence; Air-assisted dispersive liquid-liquid microextraction; Solidification; Thymol; Formaldehyde; Hantzsch reaction; Milk

Categories

Funding

  1. Russian Science Foundation [21-13-00020]
  2. Russian Science Foundation [21-13-00020] Funding Source: Russian Science Foundation

Ask authors/readers for more resources

A novel method for formaldehyde determination in milk samples was developed using derivatization and microextraction techniques without the need for cuvettes. The method allows for spectrofluorometric analysis of formaldehyde on a paper template, providing a simple and efficient approach for analytical measurements.
A derivatization and air-assisted dispersive liquid-liquid microextraction procedure with organic phase solidification on a paper template was developed for the first time. The procedure was used for the spectrofluorometric determination of formaldehyde in milk samples. The Hantzsch reaction of formaldehyde with acetylacetone in the presence of ammonia to form a derivative (3,5-diacetyl-1,4-dihydrolutidine) was implemented for the microextraction and detection of analyte. Thymol was investigated as the extraction solvent for the air-assisted dispersive liquid-liquid microextraction for the first time. In the developed procedure, molten thymol was added to the thermostated aqueous sample solution containing reagents for formaldehyde derivatization, and cloudy solution of fine thymol droplets was formed by air bubbling. After separation of phases the liquid extract phase was withdrawn with a dispenser and distributed on the black paper template in a thin layer to be solidified. The solidified extract phase on the template was inserted to a sample holder of a spectrofluorometer and fluorescence intensity was measured without using cuvettes. Under optimal experimental conditions the linear detection range was found to be 45-500 mu g L-1 with LOD calculated from a blank test, based on 3 sigma, 15 mu g L-1. The developed procedure does not require the dilution of the solid extract phase in organic solvent to be introduced in an analytical instrumentation and the use of cuvettes for spectrofluorometric detection. (C) 2021 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available