4.7 Article

Electrochemical stripping chemiluminescent sensor based on copper nanoclusters for detection of carcinoembryonic antigen

Journal

SENSORS AND ACTUATORS B-CHEMICAL
Volume 344, Issue -, Pages -

Publisher

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2021.130291

Keywords

Cu NCs; ESCL; Aptamer sensor; CEA; Luminol

Funding

  1. Natural Science Foundation of Shandong Province [ZR2018BB059, ZR2017BB084]
  2. Shandong Tai-Shan Scholar Research Fund
  3. Young Innovative Talents Introduction & Cultivation Program for Colleges and Universities of Shandong Province: Innovative Research Team on biomedical sensing and food safety Research

Ask authors/readers for more resources

A highly sensitive electrochemical stripping chemiluminescent aptamer sensor for detecting CEA was constructed based on copper nanoclusters, showing good specificity, stability and reproducibility. The sensor achieved satisfactory results in detecting actual samples, indicating potential application prospects in clinical detection.
As a new type of nano-catalytic material, copper nanoclusters (Cu NCs) have received more and more attention in various fields such as biosensors and catalysis. In this work, an electrochemical stripping chemiluminescent (ESCL) aptamer sensor based on Cu NCs was constructed for the detection of carcinoembryonic antigen (CEA). The Cu NCs were generated using DNA duplex (the CEA aptamer and its complementary strand) as template. During the ESCL detection process, Cu NCs catalyzed the reduction of H2O2 and were gradually electrochemically oxidized to Cu2+, which both promoted the decomposition of H2O2 and thus greatly improved the ECL of luminol. CEA could specifically bind with its aptamer, so the DNA duplex was damaged, causing a decrease of Cu NCs and lower ECL signals. Under the optimized conditions, the sensor achieved a high sensitivity detection of CEA with a linear range of 0.2 fg mL-1 to 1 ng mL-1 and a detection limit of 66.67 ag mL-1 (S/N = 3). In addition, the sensor exhibited good specificity, stability and reproducibility, and the detection of actual samples obtained satisfactory results, indicating that the provided strategy has potential application prospects in clinical detection.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available