4.7 Article

Highly sensitive non-enzymatic glucose sensor based on carbon nanotube microelectrode set

Journal

SENSORS AND ACTUATORS B-CHEMICAL
Volume 348, Issue -, Pages -

Publisher

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2021.130688

Keywords

Carbon nanotube; Copper nanoparticles; Electroanalysis; Glucose; Nonenzymatic

Funding

  1. Department of Chemistry at the University of Cincinnati, USA
  2. NSF [2016484]
  3. Translational Impacts
  4. Dir for Tech, Innovation, & Partnerships [2016484] Funding Source: National Science Foundation

Ask authors/readers for more resources

The study developed a nonenzymatic glucose sensor using copper nanoparticles and carbon nanotubes microelectrode set, demonstrating excellent sensitivity, low detection limit, and resistance to external interference. The sensor was successfully applied for quantifying glucose in physiological samples, showing great potential for commercial nonenzymatic glucose sensors.
In this work, a carbon nanotube microelectrode set (CNT mu-ES) was modified, in which three electrodes based on highly densified carbon nanotube fiber (HD-CNTf) cross-sections (length -40 mu m) were embedded in an inert polymer matrix with exposed open-ended CNTs at the interface. An HD-CNTf cross-section (-40 mu m diameter) electrochemically modified with copper nanoparticles (CuNPs) was used as the working electrode; a bare HDCNTf cross-section (-94 mu m diameter) was used as the counter electrode; and an HD-CNTf cross-section (-94 mu m diameter) electroplated with Ag/AgCl and then coated with NafionTM was used as a quasi-reference electrode. The electrochemical activity of the CuNPs/HD-CNTf microsensor for glucose electrooxidation was examined by cyclic voltammetry and amperometry in 0.1 M NaOH solution. As shown by amperometry studies, the proposed nonenzymatic CuNPs/HD-CNTf microsensor had a remarkably low limit of detection (28 nM) and a wide linear quantification range with an excellent sensitivity (1942 nA.mu M- 1.cm- 2). This sensitivity can be attributed to the synergetic effect of electrocatalytic CuNPs and aligned HD-CNTf, which provide excellent conductivity. The electrooxidation of glucose on the developed microsensor was free from chloride poisoning and independent of the oxygen concentration. The developed microsensor demonstrated insignificant interference from the oxidation of common interfering species and carbohydrate compounds at their physiological concentrations. Finally, the CuNPs/ HD-CNTf microsensor was successfully applied for the quantification of glucose in normal human serum and diabetic patient urine samples, demonstrating the applicability of this strategy for commercial nonenzymatic glucose sensors.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available