4.6 Article

Augmented Reality as a Tool to Guide PSI Placement in Pelvic Tumor Resections

Journal

SENSORS
Volume 21, Issue 23, Pages -

Publisher

MDPI
DOI: 10.3390/s21237824

Keywords

augmented reality; patient-specific instruments; pelvic tumor resection; 3D printing

Funding

  1. European Regional Development Fund ''Una manera de hacer Europa'' [PI18/01625]
  2. Ministerio de Ciencia e Innovacion, Instituto de Salud Carlos III [PI18/01625]

Ask authors/readers for more resources

This study proposed using augmented reality (AR) to guide and verify the placement of PSIs, showing significant differences in accuracy compared to the conventional freehand method. AR guidance prevented high osteotomy deviations, reducing maximal deviation from 54.03 mm for freehand placements to less than 5 mm.
Patient-specific instruments (PSIs) have become a valuable tool for osteotomy guidance in complex surgical scenarios such as pelvic tumor resection. They provide similar accuracy to surgical navigation systems but are generally more convenient and faster. However, their correct placement can become challenging in some anatomical regions, and it cannot be verified objectively during the intervention. Incorrect installations can result in high deviations from the planned osteotomy, increasing the risk of positive resection margins. In this work, we propose to use augmented reality (AR) to guide and verify PSIs placement. We designed an experiment to assess the accuracy provided by the system using a smartphone and the HoloLens 2 and compared the results with the conventional freehand method. The results showed significant differences, where AR guidance prevented high osteotomy deviations, reducing maximal deviation of 54.03 mm for freehand placements to less than 5 mm with AR guidance. The experiment was performed in two versions of a plastic three-dimensional (3D) printed phantom, one including a silicone layer to simulate tissue, providing more realism. We also studied how differences in shape and location of PSIs affect their accuracy, concluding that those with smaller sizes and a homogeneous target surface are more prone to errors. Our study presents promising results that prove AR's potential to overcome the present limitations of PSIs conveniently and effectively.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available