4.6 Article

Wearable Bluetooth Triage Healthcare Monitoring System

Journal

SENSORS
Volume 21, Issue 22, Pages -

Publisher

MDPI
DOI: 10.3390/s21227586

Keywords

triage; tele-triage; electronic stethoscope; piezoelectric; cardiac; respiratory; wireless

Funding

  1. NSW Smart Sensing Network (NSSN)
  2. 3Aim Solution PTY via the grant titled: A Novel Fused Sensor and Miniaturised Electronics Design for the Monitoring of aWide Range of Cardiorespiratory Parameters for Healthy Ageing

Ask authors/readers for more resources

Triage is a dynamic process at Emergency departments, involving rapid patient assessment and continuous vital signs monitoring. A wearable patient monitoring system using a ceramic piezoelectric disk shows promising results for detecting respiratory and cardiac events, suggesting it could be a hands-free monitoring device for triage assessment in emergency departments.
Triage is the first interaction between a patient and a nurse/paramedic. This assessment, usually performed at Emergency departments, is a highly dynamic process and there are international grading systems that according to the patient condition initiate the patient journey. Triage requires an initial rapid assessment followed by routine checks of the patients' vitals, including respiratory rate, temperature, and pulse rate. Ideally, these checks should be performed continuously and remotely to reduce the workload on triage nurses; optimizing tools and monitoring systems can be introduced and include a wearable patient monitoring system that is not at the expense of the patient's comfort and can be remotely monitored through wireless connectivity. In this study, we assessed the suitability of a small ceramic piezoelectric disk submerged in a skin-safe silicone dome that enhances contact with skin, to detect wirelessly both respiration and cardiac events at several positions on the human body. For the purposes of this evaluation, we fitted the sensor with a respiratory belt as well as a single lead ECG, all acquired simultaneously. To complete Triage parameter collection, we also included a medical-grade contact thermometer. Performances of cardiac and respiratory events detection were assessed. The instantaneous heart and respiratory rates provided by the proposed sensor, the ECG and the respiratory belt were compared via statistical analyses. In all considered sensor positions, very high performances were achieved for the detection of both cardiac and respiratory events, except for the wrist, which provided lower performances for respiratory rates. These promising yet preliminary results suggest the proposed wireless sensor could be used as a wearable, hands-free monitoring device for triage assessment within emergency departments. Further tests are foreseen to assess sensor performances in real operating environments.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available