4.7 Article

Field comparison of passive polyurethane foam and active air sampling techniques for analysis of gas-phase semi-volatile organic compounds at a remote high-mountain site

Journal

SCIENCE OF THE TOTAL ENVIRONMENT
Volume 803, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.scitotenv.2021.149738

Keywords

Passive air sampling; Active air sampling; Semi-volatile organic compounds; Performance reference compounds; Calibration; Field comparison

Funding

  1. Spanish Ministry of Science and Innovation [CTM2015-71832-P, PGC2018-102288-B-I00]
  2. SpanishMinistry of Science and Innovation [BES-2016-076339]

Ask authors/readers for more resources

The study demonstrates the feasibility of using PUF-PAS for air SVOC analysis in high-mountain areas, with in-situ calibration using PRCs providing suitable sampling rates. Results from PUF-PAS showed good agreement with those from PUF-AAS, with minor deviations observed for PAHs due to seasonal concentration variations.
Polyurethane foam passive air samplers (PUF-PAS) are good candidates for the determination of gas-phase semi-volatile organic compound (SVOC) air concentrations in high-mountain areas over long periods because they do not require an energy supply. However, the harsh meteorological conditions present in such locations can increase the uncertainties inherently associated to PAS sampling rates due to the many variables involved in their calculation and to the assumptions made regarding PUF diffusive uptake mechanics, which can considerably bias the resulting concentrations. Therefore, we studied the performance of PUF-PASs in a remote location in the Pyrenees mountain range for the analysis of several SVOCs in air, including polychlorobiphenyls (PCBs), hexachlorobenzene, pentachlorobenzene, polycyclic aromatic hydrocarbons (PAHs), and the less studied emerging organophosphate flame retardants (OPFRs). An in-situ PUF-PAS calibration using Performance Reference Compounds (PRCs) provided compound-and sampler-specific sampling rates, showing mean experimental errors (12%) that adequately conformed to an estimate of their expanded theoretical uncertainties (15%). This show-cases the suitability of this calibration strategy in an area with conditions beyond those typically considered in calibration efforts available to date. Moreover, gas-phase concentrations of the studied pollutants from PUF-PAS samples showed very good agreement (R-2 up to 0.91, p < 0.01) when compared to those obtained using a conventional high-volume active air sampler (PUF-AAS), with some minor deviations observed for PAHs caused by the seasonality in their atmospheric concentrations. No relevant levels of pollutants preferentially bound to the particle phase were detected in the PUF-PASs, the particle infiltration efficiency of the sampler configuration used was found to be low, and compounds typically distributed between the gas and particle phases of AAS samples revealed profiles consistent with their vapor pressures, except for some OPFRs. (C) 2021 The Authors. Published by Elsevier B.V.