4.3 Review

Role of endoscopic ultrasound-guided liver biopsy: a Meta-analysis

Related references

Note: Only part of the references are listed.
Review Gastroenterology & Hepatology

Diagnostic yield of endoscopic ultrasound-guided liver biopsy in comparison to percutaneous liver biopsy: a systematic review and meta-analysis

Antonio Facciorusso et al.

Summary: EUS-LB and PC-LB show comparable diagnostic performance and safety profiles, with some studies indicating slightly superior performance of PC-LB.

EXPERT REVIEW OF GASTROENTEROLOGY & HEPATOLOGY (2022)

Article Gastroenterology & Hepatology

A Comparative Study of 22G versus 19G Needles for EUS-Guided Biopsies for Parenchymal Liver Disease: Are Thinner Needles Better?

Harsh K. Patel et al.

Summary: This study compared the efficacy of a novel 22G Franseen-tip fine-needle biopsy device with 19G needle platforms for liver parenchyma biopsy. The results showed that the 22G Franseen-tip needle obtained more tissue fragments but had inferior specimen adequacy compared to 19G non-Tru-Cut needles.

DIGESTIVE DISEASES AND SCIENCES (2021)

Article Gastroenterology & Hepatology

Comparison of Two Specialized Histology Needles for Endoscopic Ultrasound (EUS)-Guided Liver Biopsy: A Pilot Study

Rintaro Hashimoto et al.

Summary: This study compared the efficacy of two second-generation 19G fine-needle biopsy devices for EUS-guided liver biopsy. The Franseen-tip needle group showed higher number of complete portal tracts compared to the Fork-tip needle group. Both needles demonstrated high histologic adequacy, with the right lobe of the liver yielding higher CPTs. The use of the 19G Franseen-tip needle may provide more CPTs than the 19G Fork-tip needle on a single-pass, single-actuation comparison.

DIGESTIVE DISEASES AND SCIENCES (2021)

Letter Gastroenterology & Hepatology

Emerging role of endoscopic ultrasound-guided liver biopsy

John David Chetwood et al.

Article Gastroenterology & Hepatology

Endoscopic Ultrasound-Guided Fine Needle Aspiration Using a 22-G Needle for Hepatic Lesions: Single-Center Experience

Ebru Akay et al.

Summary: This study demonstrates that EUS-FNA using a 22-G needle for the evaluation of liver masses, even with only one pass, has high aspiration and biopsy success rates along with high diagnostic accuracy rates.

CLINICAL ENDOSCOPY (2021)

Article Gastroenterology & Hepatology

Superior Specimen and Diagnostic Accuracy with Endoscopic Ultrasound-Guided Liver Biopsies Using 19-Gauge versus 22-Gauge Core Needles

Rucha M. Shah et al.

Summary: The study compared the outcomes of a single-pass, single-actuation, wet suction technique with 19 G and 22 G needles in EUS-LB, revealing that the 19 G needle provided longer core length and more complete portal tracts, resulting in superior sample adequacy and diagnostic pathology quality compared to the 22 G needle.

CLINICAL ENDOSCOPY (2021)

Article Medicine, General & Internal

Comparative Study of an Ultrasound-guided Percutaneous Biopsy and Endoscopic Ultrasound-guided Fine-needle Aspiration for Liver Tumors

Yuichi Takano et al.

Summary: Both percutaneous biopsy and EUS-FNA show equivalent diagnostic qualities for liver tumors, although EUS-FNA tends to be associated with fewer adverse events. A complete understanding of the characteristics of each procedure is essential when choosing the best biopsy method for each particular case.

INTERNAL MEDICINE (2021)

Article Oncology

Diagnostic Yield of Endoscopic Ultrasound-Guided Liver Biopsy in Comparison to Percutaneous Liver Biopsy: A Two-Center Experience

Antonio Facciorusso et al.

Summary: This study compared percutaneous and endoscopic ultrasound methods for liver biopsy, with results showing that although percutaneous liver biopsy yielded specimens with greater total sample length, the diagnostic adequacy and accuracy were similar between the two procedures.

CANCERS (2021)

Article Acoustics

Accuracy of endoscopic ultrasound-guided biopsy of focal liver lesions

Vlad Andrei Ichim et al.

MEDICAL ULTRASONOGRAPHY (2020)

Article Gastroenterology & Hepatology

Sa1465 SHARKCORE™ VERSUS ACQUIRE™: A PROSPECTIVE, HEAD-TO-HEAD COMPARISON OF ENDOSCOPIC ULTRASOUND-GUIDED LIVER BIOPSY

Soorya N. Aggarwal et al.

GASTROINTESTINAL ENDOSCOPY (2020)

Article Gastroenterology & Hepatology

Endoscopic ultrasound-guided liver biopsy using a 20-gauge fine needle biopsy needle with the wet-heparinized suction technique

Gurhan Sisman et al.

EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY (2020)

Article Gastroenterology & Hepatology

Comparison of EUS-guided versus percutaneous and transjugular approaches for the performance of liver biopsies

Asim Shuja et al.

DIGESTIVE AND LIVER DISEASE (2019)

Review Gastroenterology & Hepatology

Efficacy and safety of EUS-guided liver biopsy: a systematic review and meta-analysis

Babu P. Mohan et al.

GASTROINTESTINAL ENDOSCOPY (2019)

Review Health Care Sciences & Services

In Cochrane reviews, risk of bias assessments for allocation concealment were frequently not in line with Cochrane's Handbook guidance

Ivana Propadalo et al.

JOURNAL OF CLINICAL EPIDEMIOLOGY (2019)

Article Gastroenterology & Hepatology

Endoscopic ultrasound-guided liver biopsy using a 22-G fine needle biopsy needle: a prospective study

Muhammad K. Hasan et al.

ENDOSCOPY (2019)

Meeting Abstract Gastroenterology & Hepatology

EUS-GUIDED LIVER BIOPSY USING 22G FNB VS. 19G FNB NEEDLES: A PROSPECTIVE COMPARISON OF CORE SPECIMEN SIZE AND DIAGNOSTIC ADEQUACY

Ishfaq Bhat et al.

GASTROINTESTINAL ENDOSCOPY (2019)

Article Gastroenterology & Hepatology

Endoscopic ultrasound-guided biopsy in chronic liver disease: a randomized comparison of 19-G FNA and 22-G FNB needles

Shaffer R. S. Mok et al.

ENDOSCOPY INTERNATIONAL OPEN (2019)

Article Gastroenterology & Hepatology

Comparison of Endoscopic Ultrasound Biopsy Needles for Endoscopic Ultrasound-Guided Liver Biopsy

Armen Eskandari et al.

CLINICAL ENDOSCOPY (2019)

Article Gastroenterology & Hepatology

A prospective pilot comparison of wet and dry heparinized suction for EUS-guided liver biopsy (with videos)

Shaffer R. S. Mok et al.

GASTROINTESTINAL ENDOSCOPY (2018)

Article Gastroenterology & Hepatology

Optimizing EUS-guided liver biopsy sampling: comprehensive assessment of needle types and tissue acquisition techniques

Allison R. Schulman et al.

GASTROINTESTINAL ENDOSCOPY (2017)

Letter Gastroenterology & Hepatology

Endoscopic Ultrasound-guided Parenchymal Liver Biopsy: Single Center Experience of a New Dedicated Core Needle

Neil D. Shah et al.

CLINICAL GASTROENTEROLOGY AND HEPATOLOGY (2017)

Article Gastroenterology & Hepatology

EUS-guided liver biopsy provides diagnostic samples comparable with those via the percutaneous or transjugular route

Jonh J. Pineda et al.

GASTROINTESTINAL ENDOSCOPY (2016)

Article Gastroenterology & Hepatology

EUS-guided liver biopsy for parenchymal disease: a comparison of diagnostic yield between two core biopsy needles

Michael Sai Lai Sey et al.

GASTROINTESTINAL ENDOSCOPY (2016)

Review Gastroenterology & Hepatology

Endoscopic ultrasound-guided liver biopsy

Parth J. Parekh et al.

ENDOSCOPIC ULTRASOUND (2015)

Article Gastroenterology & Hepatology

Histological adequacy of EUS-guided liver biopsy when using a 19-gauge non-Tru-Cut FNA needle

Niraj Gor et al.

GASTROINTESTINAL ENDOSCOPY (2014)

Editorial Material Gastroenterology & Hepatology

Endoscopic ultrasound-guided liver biopsy in pediatric patients

Amitpal S. Johal et al.

ENDOSCOPIC ULTRASOUND (2014)

Article Pathology

How often do our liver core biopsies reach current definitions of adequacy?

Eve Fryer et al.

JOURNAL OF CLINICAL PATHOLOGY (2013)

Article Gastroenterology & Hepatology

d High yield of same-session EUS-guided liver biopsy by 19-gauge FNA needle in patients undergoing EUS to exclude biliary obstruction

Stavros N. Stavropoulos et al.

GASTROINTESTINAL ENDOSCOPY (2012)

Editorial Material Public, Environmental & Occupational Health

Critical evaluation of the Newcastle-Ottawa scale for the assessment of the quality of nonrandomized studies in meta-analyses

Andreas Stang

EUROPEAN JOURNAL OF EPIDEMIOLOGY (2010)

Article Gastroenterology & Hepatology

Initial experience with EUS-guided Tru-cut biopsy of benign liver disease

John DeWitt et al.

GASTROINTESTINAL ENDOSCOPY (2009)

Review Gastroenterology & Hepatology

Liver Biopsy

Don C. Rockey et al.

HEPATOLOGY (2009)

Review Medicine, General & Internal

Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement

David Moher et al.

PLOS MEDICINE (2009)

Article Gastroenterology & Hepatology

Adequacy of Endoscopic Ultrasound Core Needle Biopsy Specimen of Nonmalignant Hepatic Parenchymal Disease

Ferga C. Gleeson et al.

CLINICAL GASTROENTEROLOGY AND HEPATOLOGY (2008)

Article Gastroenterology & Hepatology

Histopathologic variability between the right and left lobes of the liver in morbidly obese patients undergoing roux-en-Y bypass

Steven P. Larsow et al.

CLINICAL GASTROENTEROLOGY AND HEPATOLOGY (2007)

Review Gastroenterology & Hepatology

Percutaneous liver biopsy in clinical practice

Bandar Al Knawy et al.

LIVER INTERNATIONAL (2007)

Article Gastroenterology & Hepatology

Importance of specimen size in accurate needle liver biopsy evaluation of patients with chronic hepatitis C

TD Schiano et al.