Software-Based Evaluation of Optimization Potential for Clinical MRI Scanners in Radiology

Publisher

GEORG THIEME VERLAG KG
DOI: 10.1055/a-1659-8821

Keywords

health policy and practice; scheduling; optimization; MR imaging

Ask authors/readers for more resources

Using a software-based analysis, this study examined the examination times and changeover times of two clinically highly applied MRI scanners at a university hospital for radiology. The results showed little potential for optimization in examination planning, and coil exchanges had a small impact on changeover times.
Objective The aim of the study was to use a software application to analyze the examination times and changeover times of two clinically highly applied MRI scanners at a university hospital for radiology and to evaluate whether this could result in optimization potential for examination planning in the daily clinical routine of MRI diagnostics. Materials and Methods Based on the newly developed software application Teamplay Usage (Siemens Healthineers, Germany), the examinations carried out on two MRI scanners (1.5T and 3T) were investigated within an analysis period of 12 months with regard to the type of examination and its duration. In addition, compliance with the previously defined planning time (30, 45, 60 min.) was checked and deviations were analyzed. In addition, the changeover times between the examinations were determined and a possible influence due to the exchange of MRI coils was investigated for a selection of change combinations. Results For the total of 7184 (1.5 T: 3740; 3T: 3444) examinations included in the study, the median examination time was 43:02 minutes (1.5 T: 43:17 min.; 3 T: 42:45 min.). The ten most frequent types of examinations per MRI scanner were completed within the predefined plan time of 54.5 % (1.5T) and 51.9% (3 T), taking into account a previously defined preparation and post-processing time of 9 minutes per examination. Overall, more time was spent on examinations with a planned time of 30 minutes, whereas the majority of the examinations planned with 45 minutes were also completed within this time. Examinations with a planned time of 60 minutes usually took less time. A comparison between the planned time and the determined examination duration of the most common types of examinations showed overall a slight potential for optimization. Coil exchanges between two examinations had a small, but statistically not significant effect on the median changeover time (p = 0.062). Conclusion Utilizing a software-based analysis, a detailed overview of the type of examination, examination duration, and changeover times of frequently used clinical MRI scanners could be obtained. In the clinic examined, there was little potential for optimization of examination planning. An exchange of MRI coils necessary for different types of examination only had a small effect on the changeover times.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.0
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available