4.7 Article

Multi-objective optimization of a renewable power supply system with underwater compressed air energy storage for seawater reverse osmosis under two different operation schemes

Journal

RENEWABLE ENERGY
Volume 181, Issue -, Pages 71-90

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.renene.2021.09.041

Keywords

Renewable power supply system; Reverse osmosis; Underwater compressed air energy storage; Multi-objective optimization; Carbon emission

Funding

  1. National Natural Science Foundation of China [51876152]

Ask authors/readers for more resources

This study focused on water supply in rural islands or coastal areas, proposing a renewable driven power supply system for RO plants and conducting a multi-objective optimization analysis of energy, economic, and environmental factors. The results showed that the optimal grid-connected scheme had considerable economic profit, while the off-grid scheme had no revenue. Both schemes, however, could significantly reduce carbon emissions.
Water supply in rural islands or coastal areas is a basic task for people's livelihood. The all-pervading reverse osmosis (RO) technology is an energy-intensive process. To achieve sustainability goals, the development of renewable driven power supply system for RO plant is significant. Nowadays, the energy, economic and environmental indicators have rarely simultaneously investigated for the type of renewable power supply system with underwater compressed air energy storage (UW-CAES) for RO plant. In this paper, an energy-economic-environmental trade-off multi-objective optimization for such system is proposed in both grid-connected and off-grid schemes. A bi-level optimization strategy based on MOPSO algorithm and TOPSIS method is adopted to seek the optimal configuration and energy management strategy. A real-world case is implemented to demonstrate this method. The results show that the TPC/COE/EC set in optimal grid-connected scheme system is 3.716 x 10(6)Y/0.814YkWh(-1)/795.922 kg with a configuration of 511 PVs, 12 WTs and a 900 m(3) bag volume in UW-CAES. Whereas, the TPC/COE/EC in optimal off-grid system is 4.076 x 10(6)Y/2.305 kWh(-1)/566.254 kg with a 705/8/900 m(3) configuration. In energy perspective, both schemes can match the load well. In economic perspective, the grid-connected scheme has a considerable profit, whereas the off-grid has no revenue. In environmental perspective, both schemes can reduce the carbon emission remarkably. (C) 2021 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available