BowTie analysis of rooftop grid-connected photovoltaic systems

Journal

PROCESS SAFETY PROGRESS
Volume 41, Issue -, Pages S106-S117

Publisher

WILEY
DOI: 10.1002/prs.12338

Keywords

BowTie analysis; fire safety; photovoltaic; PV fire; rooftop PV system

Funding

  1. Akaun Amanah Industri Bekalan Elektrik (AAIBE) [JAAIBE 3/2019/11/Bil.3]
  2. Universiti Putra Malaysia [6300252]

Ask authors/readers for more resources

The rapid growth in worldwide PV installations has led to an increasing trend in fire incidents involving PV systems, particularly on rooftops. Arc fault is identified as the primary cause of PV fires, with consequences including respiratory poisons, electrical shock, falls from heights, asset damage, and fire propagation. Additional measures are suggested to mitigate the high risk of electrical shock, especially for firefighters and surrounding individuals.
With the rapid growth of the worldwide photovoltaic (PV) installation, the number of fire incidents involving PV systems also shows an increasing trend. Several studies revealed that installing PV systems on the rooftop has introduced an additional fire risk to the building. Therefore, risk assessment is required to identify the possible cause of fire initiation involving PV systems and subsequently provide the solar industry with fire risk information regarding PV faults. A BowTie analysis of rooftop grid-connected PV systems was conducted, where initiation of ignition was determined as the hazard and PV fires as the loss event. Four threats in the BowTie analysis were identified using fault tree analysis, that is, arc fault, ground fault, hotspot effect at PV modules, and overheating. Arc fault contributes the most to PV fire incidents, while poor installation of PV systems was found to be the primary underlying cause of all PV fault scenarios. The main factor is due to lack of fire safety knowledge and negligence behavior of the installers. The consequences of PV fires in the BowTie diagram were investigated from the event tree analysis. Twelve possible outcomes were identified and regrouped to five consequences, that is, respiratory poisons, electrical shock, fall from heights, asset damage, and fire propagation. The evaluation of the consequences of PV fire shows that electrical shock poses a very high risk to the surrounding people, including firefighters. Additional measures are proposed to reduce the impact of electric shock.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.1
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available