4.4 Article

Fabrication and performance evaluation of parallel plate avalanche counters for RISP

Publisher

ELSEVIER
DOI: 10.1016/j.nima.2021.165734

Keywords

Heavy-ion detectors; Particle tracking detectors; Particle tracking detectors (Gaseous detectors)

Funding

  1. National Research Foundation of Korea (NRF) - Ministry of Education, Republic of Korea [NRF-2018R1D1A1B070 48941]
  2. NRF of Korea [2013M7A1A1075764]
  3. Korea University
  4. Rare Isotope Science Project of the Institute for Basic Science - Ministry of Science and ICT

Ask authors/readers for more resources

In this study, position-sensitive parallel plate avalanche counters (PPACs) were fabricated and tested for the Rare Isotope Science Project in Korea. The detectors showed a detection efficiency greater than 99% and position and time resolutions of 380 μm and 520 ps FWHM, respectively, indicating their potential for high performance in detecting rare isotopes.
We have fabricated and tested position-sensitive parallel plate avalanche counters (PPACs) for the Rare Isotope Science Project in Korea. These detectors have active areas of 10 cm x 10 cm with a stripped electrode structure. A delay line readout was employed to obtain the position information. Detector performance was tested with an Am-241 alpha source. The detection efficiency, position, and time resolutions were studied with C3F8 gas pressures from 4 to 28 Torr and high voltages from 650 to 1100 V. Detection efficiency was greater than 99%. The position and time resolutions were measured to be 380 mu m and 520 ps of full-width at half maximum (FWHM), respectively.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.