4.6 Article

Development and validation of a deep-learning model for detecting brain metastases on 3D post-contrast MRI: a multi-center multi-reader evaluation study

Journal

NEURO-ONCOLOGY
Volume 24, Issue 9, Pages 1559-1570

Publisher

OXFORD UNIV PRESS INC
DOI: 10.1093/neuonc/noac025

Keywords

automatic detection; brain metastases; cascaded convolutional network; MRI

Ask authors/readers for more resources

This study developed a multi-scale cascaded convolutional network for brain metastasis detection and validated its accuracy. The results showed that using this system can improve the detection sensitivity of doctors and reduce reading time.
Background Accurate detection is essential for brain metastasis (BM) management, but manual identification is laborious. This study developed, validated, and evaluated a BM detection (BMD) system. Methods Five hundred seventy-three consecutive patients (10 448 lesions) with newly diagnosed BMs and 377 patients without BMs were retrospectively enrolled to develop a multi-scale cascaded convolutional network using 3D-enhanced T1-weighted MR images. BMD was validated using a prospective validation set comprising an internal set (46 patients with 349 lesions; 44 patients without BMs) and three external sets (102 patients with 717 lesions; 108 patients without BMs). The lesion-based detection sensitivity and the number of false positives (FPs) per patient were analyzed. The detection sensitivity and reading time of three trainees and three experienced radiologists from three hospitals were evaluated using the validation set. Results The detection sensitivity and FPs were 95.8% and 0.39 in the test set, 96.0% and 0.27 in the internal validation set, and ranged from 88.9% to 95.5% and 0.29 to 0.66 in the external sets. The BMD system achieved higher detection sensitivity (93.2% [95% CI, 91.6-94.7%]) than all radiologists without BMD (ranging from 68.5% [95% CI, 65.7-71.3%] to 80.4% [95% CI, 78.0-82.8%], all P < .001). Radiologist detection sensitivity improved with BMD, reaching 92.7% to 95.0%. The mean reading time was reduced by 47% for trainees and 32% for experienced radiologists assisted by BMD relative to that without BMD. Conclusions BMD enables accurate BM detection. Reading with BMD improves radiologists' detection sensitivity and reduces their reading times.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available