4.7 Article

Comparing different approaches for stellar intensity interferometry

Journal

MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY
Volume 512, Issue 2, Pages 1722-1729

Publisher

OXFORD UNIV PRESS
DOI: 10.1093/mnras/stac489

Keywords

instrumentation: high angular resolution; instrumentation: interferometers; telescopes; stars: imaging

Funding

  1. Deutsche Forschungsgemeinschaft [FU 1093/3-1, 426212122]

Ask authors/readers for more resources

Stellar intensity interferometers can overcome the limitations of existing amplitude interferometers and measure the correlation signal of starlight without relying on phase coherence. Different operation modes can achieve high signal-to-noise ratio measurements.
Stellar intensity interferometers correlate photons within their coherence time and could overcome the baseline limitations of existing amplitude interferometers. Intensity interferometers do not rely on phase coherence of the optical elements and thus function without high-grade optics and light combining delay lines. However, the coherence time of starlight observed with realistic optical filter bandwidths (> 0.1 nm) is usually much smaller than the time resolution of the detection system (> 10 ps), resulting in a greatly reduced correlation signal. Reaching high signal-to-noise ratio in a reasonably short measurement time can be achieved in different ways: either by increasing the time resolution, which increases the correlation signal height, or by increasing the photon rate, which decreases statistical uncertainties of the measurement. We present laboratory measurements employing both approaches and directly compare them in terms of signal-to-noise ratio. A high-time-resolution interferometry setup designed for small-to-intermediate-sized optical telescopes and thus lower photon rates (diameters < some metres) is compared to a setup capable of measuring high photon rates, which is planned to be installed at Cherenkov telescopes with dish diameters of > 10 m. We use a xenon lamp as a common light source simulating starlight. Both setups measure the expected correlation signal and work at the expected shot-noise limit of statistical uncertainties for measurement times between 10 min and 23 h. We discuss the quantitative differences in the measurement results and give an overview of suitable operation regimes for each of the interferometer concepts.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available