4.7 Article

Ultrasensitive determination of underivatized adamantane analogs in biological fluids by capillary electrophoresis with contactless conductivity detection

Journal

MICROCHEMICAL JOURNAL
Volume 169, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.microc.2021.106602

Keywords

Filed amplified sample stacking; Body fluids; Capillary electrophoresis; Ultrasound-assisted dispersive liquid-liquid microextraction; Adamantane drugs; Capacitively coupled contactless conductivity detection

Funding

  1. Ministry of Science and Technology of Taiwan [MOST 109-2113-M-017002]

Ask authors/readers for more resources

The study presents a highly efficient method for detecting underivatized adamantane analogs by integrating UADLLME, FASS-CE, and C4D technologies, achieving satisfactory results through online concentration during CE separation and proving the feasibility and accuracy for determination of MT, AT, and RT in human serum and urine.
Separation techniques are promising for the detection of adamantane analogs with various functional groups. The derivatization of adamantane analogs with chromophores or fluorophores should be conducted using a separation technique combined with a common ultraviolet-visible or fluorescence detector. However, limited research has been conducted on underivatized adamantane analogs. Therefore, we present a highly rapid and sensitive method for detecting underivatized adamantane analogs by integrating ultrasound-assisted dispersive liquid-liquid microextraction (UADLLME), field-amplified sample stacking (FASS)-related capillary electropho-resis (CE), and capacitively coupled contactless conductivity detection (C4D). In the proposed system, UADLLME is used for sample clean up and analyte enrichment, whereas FASS-related CE provides on-line concentration of underivatized adamantane analogs during CE separation. A mixture of memantine (MT), amantadine (AT), and rimantadine (RT) was separated at baseline within 8 min through the application of optimized UADLLME (mixing extraction solvent, 50 mu L of 1,1,2,2-tetrachloroethane (C2H2Cl4) and dispersive solvent, 200 mu L of acetonitrile; mixing solution was injected into 1 mL of the sample solution at pH 12.5), FASS (buffer, 1.5 M acetic acid; additive, 0.05 mM beta-cyclodextrin; pH 2.5), and C4D (amplitude, 2 Vpp; frequency, 500 kHz). The calibration curve exhibited acceptable linearity, with a coefficient of determination higher than 0.99. The limits of detection (signal-to-noise ratio of 3) were estimated to be 0.9, 1.0, and 1.2 nM for MT, AT, and RT, respectively. The relative standard deviations of peak areas varied from 8.9% to 9.3% (n = 5), whereas the sensitivity improve-ment of three underivatized adamantane analogs ranged from 1342 to 1766. The feasibility and accuracy of the present method for the determination of MT, AT, and RT in human serum and urine was satisfactorily confirmed by the excellent recovery and relative error. The proposed method exhibited high enrichment factors and offers excellent precision, high accuracy, and a short analysis time.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available