4.6 Article

The challenges facing deep learning-based catheter localization for ultrasound guided high-dose-rate prostate brachytherapy

Journal

MEDICAL PHYSICS
Volume 49, Issue 4, Pages 2442-2451

Publisher

WILEY
DOI: 10.1002/mp.15522

Keywords

deep learning; high-dose-rate prostate brachytherapy; image segmentation

Funding

  1. Saskatchewan Cancer Agency [421376]
  2. University of Saskatchewan

Ask authors/readers for more resources

In this study, a deep learning model was developed for automated catheter reconstruction and its performance was investigated. The model achieved promising results on a large clinical dataset but faced challenges such as ultrasound artifacts and image degradation.
Background Automated catheter localization for ultrasound guided high-dose-rate prostate brachytherapy faces challenges relating to imaging noise and artifacts. To date, catheter reconstruction during the clinical procedure is performed manually. Deep learning has been successfully applied to a wide variety of complex tasks and has the potential to tackle the unique challenges associated with multiple catheter localization on ultrasound. Such a task is well suited for automation, with the potential to improve productivity and reliability. Purpose We developed a deep learning model for automated catheter reconstruction and investigated potential factors influencing model performance. The model was designed to integrate into a clinical workflow, with a proposed reconstruction confidence metric to aid in planner verification. Methods Datasets from 242 patients treated from 2016 to 2020 were collected retrospectively. The anonymized dataset comprises 31,000 transverse images reconstructed from 3D sagittal ultrasound acquisitions and 3500 implanted catheters manually localized by the planner. Each catheter was retrospectively ranked based on the severity of imaging artifacts affecting reconstruction difficulty. The U-NET deep learning architecture was trained to localize implanted catheters on transverse images. A fivefold cross-validation method was used, allowing for evaluation over the entire dataset. The postprocessing software combined the predictions with patient-specific implant information to reconstructed catheters in 3D space, uniquely matched to the implanted grid positions. A reconstruction confidence metric was calculated based on the number and probability of localized predictions per catheter. For each patient, deep learning prediction and postprocessing reconstruction were completed in under 2 min on a nonperformance PC. Results Overall, 80% of catheter reconstructions were accurate, within 2 mm along 90% of the length. The catheter tip was often not detected and required extrapolation during reconstruction. The reconstruction accuracy was 89% for the easiest catheter ranking and decreased to 13% for the highest difficulty ranking, when the aid of live ultrasound would have been recommended. Even when limited to the easiest ranked catheters, the reconstruction accuracy decreased at distal grid positions, down to 50%. Individual implantation style was found to influence the frequency of severe artifacts, slightly impacting the model accuracy. A reconstruction confidence metric identified the difficult catheters, removed the observed individual variation, and increased the overall accuracy to 91% while excluding 27% of the reconstructions. Conclusions The deep learning model localized implanted catheters over a large clinical dataset, with overall promising results. The model faced challenges due to ultrasound artifacts and image degradation distal to the probe, underlining the continued importance of maintaining image quality and minimizing artifacts. A potential workflow for integration into the clinical procedure was demonstrated, including the use of a confidence metric to predict low accuracy reconstructions. Comparison between models evaluated on different datasets should also consider underlying differences, such as the frequency and severity of imaging artifacts.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available