4.4 Article

Sensitivity limitations of high-resolution perfusion-based human fMRI at 7 Tesla

Journal

MAGNETIC RESONANCE IMAGING
Volume 84, Issue -, Pages 135-144

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.mri.2021.09.014

Keywords

Perfusion imaging; High-resolution fMRI; Blood oxygenation-level dependent fMRI; Cerebral blood flow-based fMRI

Funding

  1. National Institute of Neurological Disorders and Stroke, National Institutes of Health

Ask authors/readers for more resources

The study investigated the practical resolution limits of perfusion-weighted fMRI in human visual stimulation experiments. Results showed that at high resolution, perfusion-weighted fMRI had lower sensitivity than BOLD, potentially compromising the detection of visual activation.
The study of the brain's functional organization at laminar and columnar level of the cortex with blood oxygenation-level dependent (BOLD) functional MRI (fMRI) is affected by the contribution of large veins downstream from the microvascular response to brain activity. Blood volume-and especially perfusion-based techniques may reduce this problem because of their reduced sensitivity to venous effects, but may not allow the same spatial resolution because of smaller signal changes associated with brain activity. Here we investigated the practical resolution limits of perfusion-weighted fMRI in human visual stimulation experiments. For this purpose, we used a highly sensitive, single-shot perfusion labeling (SSPL) technique at 7 T and compared sensitivity to detect visual activation at low (2 mm, n = 10) and high (1 mm, n = 8) nominal isotropic spatial, and 3 s temporal, resolution with BOLD in 51/2-minute-long experiments. Despite the smaller absolute signal change with activation, 2 mm resolution SSPL yielded comparable sensitivity to BOLD. This was attributed to a superior suppression of physiological noise with SSPL. However, at 1 mm nominal resolution, SSPL sensitivity fell on average at least 42% below that of BOLD, and detection of visual activation was compromised. This is explained by the fact that at high resolution, with both techniques, typically thermal noise rather than physiological noise dominates sensitivity. The observed sensitivity loss implies that to perform 1-mm resolution, perfusion weighted fMRI with a robustness similar to BOLD, scan times that are almost 3 times longer than the comparable BOLD experiment are required. This is in line with or slightly better than previous comparisons between perfusion weighted fMRI and BOLD. The lower sensitivity has to be weighed against the spatial fidelity advantages of high-resolution perfusion-weighted fMRI.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available