4.5 Article

Aortic Root Anatomy Is Related to the Bicuspid Aortic Valve Phenotype

Journal

Publisher

MOSBY-ELSEVIER
DOI: 10.1016/j.echo.2021.11.012

Keywords

Bicuspid aortic valve; Aortic aneurism; CT; Transthoracic echocardiography; Aortic root; TTE

Ask authors/readers for more resources

This study describes the asymmetry of bicuspid aortic valve (BAV) and its impact on aortic root diameter measurements obtained using transthoracic echocardiography. The study found that the orientation of the valve opening differed from the orientation of the largest root diameter in both groups of BAV. The parasternal long-axis view on transthoracic echocardiography significantly underestimated the maximal aortic root diameter in one group and modestly underestimated it in the other group.
Background: Bicuspid aortic valve (BAV) is associated with an asymmetric (not circular) aortic root, resulting in variability in the aortic root diameter measurements obtained using different techniques. The objective of this study was to describe aortic root asymmetry, including its orientation in the thorax, in relation to the various phenotypes of BAV and its impact on aortic root diameter measurements obtained using transthoracic echocardiography. Methods: Aortic root asymmetry, orientation of the largest root diameter, and orientation of the valve opening were studied using computed tomographic scans of patients with BAV without significant aortic valve dysfunction referred for evaluation of a thoracic aortic aneurysm. Eighty-five patients with BAV were evaluated; BAV with fusion of the left and the right coronary cusps (L-R BAV), with or without raphe (n = 63), was compared with BAV with fusion of the right coronary and noncoronary cusps (N-R BAV), with or without raphe (n = 22). Results: Asymmetry of the aortic root and its orientation in the thorax can be predicted from BAV phenotype: orientation of the valve opening differed from orientation of the largest root diameter by nearly 75 degrees in both groups. The angle of the largest root diameter with the reference sagittal plane was 64.3 degrees in the L-R BAV group versus 143.1 degrees in the N-R BAV group (P < .0001). Therefore, using the parasternal long-axis view on transthoracic echocardiography, in N-R BAV, the ultrasound beam is roughly parallel to the valve opening orientation and almost orthogonal to the maximum diameter of the root. On the contrary, in L-R BAV, the ultrasound beam is roughly perpendicular to the valve opening orientation and almost parallel to the maximum diameter of the root. Consequently, the parasternal long-axis view on transthoracic echocardiography significantly underestimates maximal aortic root diameter in N-R BAV and modestly underestimates root diameter in L-R BAV (-6.1 +/- 0.96 vs-2.3 +/- 0.47 mm, P = .0008). Conclusions: Aortic root morphology in patients with BAV can be predicted by BAV phenotype: the largest root diameter is roughly perpendicular to the orientation of the valve opening. Therefore, echocardiographic measurements according to present recommendations (parasternal long-axis view) underestimate maximal diameter in patients with N-R BAV.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available