4.6 Article

Low-dissipation model of three-terminal refrigerator: performance bounds and comparative analyses

Journal

Publisher

IOP Publishing Ltd
DOI: 10.1088/1751-8121/ac47b0

Keywords

finite-time cycle; low-dissipation model; three-terminal refrigerator; performance bounds; comparative analyses

Funding

  1. National Natural Science Foundation of China [11405032, 61773121]
  2. University of Salamanca

Ask authors/readers for more resources

In this paper, a general non-combined model of a three-terminal refrigerator beyond specific heat transfer mechanisms is established based on the low-dissipation assumption. The relation between the optimized cooling power and the corresponding coefficient of performance (COP) is analytically derived, and the upper and lower bounds of the maximum cooling power (CMP) are obtained. It is found that the upper bounds are the same, whereas the lower bounds are quite different, indicating that the claimed universal equivalence for the combined and non-combined models is invalid within the frame of low-dissipation assumption.
In the present paper, a general non-combined model of three-terminal refrigerator beyond specific heat transfer mechanisms is established based on the low-dissipation assumption. The relation between the optimized cooling power and the corresponding coefficient of performance (COP) is analytically derived, according to which the COP at maximum cooling power (CMP) can be further determined. At two dissipation asymmetry limits, upper and lower bounds of CMP are obtained and found to be in good agreement with experimental and simulated results. Additionally, comparison of the obtained bounds with previous combined model is presented. In particular it is found that the upper bounds are the same, whereas the lower bounds are quite different. This feature indicates that the claimed universal equivalence for the combined and non-combined models under endoreversible assumption is invalid within the frame of low-dissipation assumption. Then, the equivalence between various finite-time thermodynamic models needs to be reevaluated regarding multi-terminal systems. Moreover, the correlation between the combined and non-combined models is further revealed by the derivation of the equivalent condition according to which the identical upper bounds and distinct lower bounds are theoretically shown. Finally, the proposed non-combined model is proved to be the appropriate model for describing various types of thermally driven refrigerator. This work may provide some instructive information for the further establishments and performance analyses of multi-terminal low-dissipation models.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available