Importance of frame rate for the measurement of strain and synchrony in fetuses using speckle tracking echocardiography

Journal

JOURNAL OF PERINATAL MEDICINE
Volume 50, Issue 2, Pages 176-184

Publisher

WALTER DE GRUYTER GMBH
DOI: 10.1515/jpm-2021-0215

Keywords

dyssynchrony; fetal; frame rate; speckle tracking echocardiography; strain; synchrony

Ask authors/readers for more resources

This study aimed to assess the influence of frame rate settings on longitudinal strain and mechanical synchrony values in Speckle Tracking Echocardiography (STE) of healthy fetuses. The results showed that higher frame rates significantly increased longitudinal strain values, but had no significant impact on mechanical synchrony values. Therefore, selecting higher frame rates can provide more accurate cardiac examination in fetal Speckle Tracking Echocardiography.
Objectives To assess the influence of frame rate settings on longitudinal strain (LS) and mechanical synchrony (SYN) values in Speckle Tracking Echocardiography (STE) of healthy fetuses. Methods In this prospective study, we collected transversal or apical four-chamber-views of 121 healthy fetuses between 20 and 38 weeks of gestation using three different frame rate (FR) settings (>= 110, 100 +/- 10, 60 +/- 10 frames per second). We assessed the segmental and the global LS of both ventricles (2C) and of the left ventricle (LV) offline with QLab 10.8 (Philips Medical Systems, Andover, MA, USA). Inter- and intraventricular SYN were calculated as time difference in peak myocardial strain between the mid-segments of left and right ventricle (interventricular, 2C_Syn) and lateral wall and septum of the left ventricle (intraventricular, LV_Syn), respectively. Results In 84.3% STE was feasible at all three FR settings. The LS increased in both views at higher FRs to a statistically noticeable extent. SYN measurements and the absolute differences at patient level between the FR settings showed no statistically noticeable alterations. Conclusions STE is feasible at low and high FR settings. SYN emerges to be a robust parameter for fetal STE as it is less affected by the FR. High FRs enable high temporal resolutions and thus an accurate examination of fetal hearts. Future research for the technical implementation of tailored fetal STE software is necessary for reliable clinical application.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available