4.7 Article

Simultaneous Measurement of Temperature and Relative Humidity Using Cascaded C-shaped Fabry-Perot interferometers

Journal

JOURNAL OF LIGHTWAVE TECHNOLOGY
Volume 40, Issue 4, Pages 1209-1215

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JLT.2021.3127525

Keywords

Temperature measurement; Optical fibers; Optical fiber sensors; Temperature sensors; Sensitivity; Humidity; Humidity measurement; C-shaped fiber; fabry-perot interferometer; relative humidity; sensitivity matrix; simultaneous measurement

Funding

  1. China Postdoctoral Science Foundation
  2. National Natural Science Foundation of China [61903073]
  3. Fundamental Research Funds for the Central Universities [N2004011]
  4. Australian Research Council Future Fellowship [FT200100154]
  5. Optofab Node of the Australian National Fabrication Facility utilizing Commonwealth and South Australian State Government
  6. Australian Research Council [FT200100154] Funding Source: Australian Research Council

Ask authors/readers for more resources

This paper demonstrates a novel platform for simultaneous measurement of relative humidity and temperature using dual Fabry-Perot interferometers based on C-shaped fiber. The sensor has a simple structure, excellent stability, and high sensitivity, and has a broad application prospect.
In this paper, a novel platform for simultaneous measurement of relative humidity (RH) and temperature using dual Fabry-Perot interferometers (FPIs) based on C-shaped fiber was demonstrated. The sensor was composed by splicing two sections of C-shaped fiber between single mode fiber (SMF). Polydimethylsiloxane (PDMS) and polyvinyl alcohol (PVA) are filled in the two sections of C-shaped fibers to increase sensitivity to temperature and RH. This is the first demonstration that solid polymer materials can be added to the C-shaped fiber interferometers for sensing. In our experiment, RH sensitivities of -0.128 nm/%RH and 0.038 nm/%RH in the range of 20%RH to 45%RH, and temperature sensitivities of 0.022 nm/degrees C and -0.722 nm/degrees C in the temperature range of 15 degrees C to 45 degrees C, were acquired for dual FPIs, respectively. We verified that it is possible to use the sensitivity matrix method to measure two parameters simultaneously. In addition, it has the benefits of simple structure, excellent stability and high sensitivity, and has a broad application prospect in agriculture, food processing and environmental measurement.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available