Journal
JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME
Volume 144, Issue 3, Pages -Publisher
ASME
DOI: 10.1115/1.4053296
Keywords
power system simulator; hospital building; nanogrid; disaster; emergency diesel engine generator; photovoltaics; AC frequency; energy conversion; systems; energy systems analysis; power (co-) generation; renewable energy
Categories
Funding
- JST RISTEX
Ask authors/readers for more resources
This study examines the impact of private generators in hospital buildings on supply-demand balance and power quality during disaster conditions. It found that the fluctuation of photovoltaic panel output can be suppressed by increasing the moving average time and reducing the feedback gain of storage batteries.
In hospitals, the energy supply is the key to ensuring modern medical care even during power outages due to a disaster. This study qualitatively examined whether the supply-demand balance can be stabilized by the private generator prepared by the hospital building during stand-alone operations under disaster conditions. In the nanogrid of the hospital building, the power quality was examined based on the AC frequency, which characterizes the supply-demand balance. Gas engine generators, emergency diesel generators, photovoltaic panels, and storage batteries were presumed to be the private generators in the hospital building. The output reference values for the emergency diesel and gas engine generators were set using droop control, and the C/D controller-enabled synchronized operation. In addition, to keep the AC frequency fluctuation minor, the photovoltaic panels were designed to suppress the output fluctuation using storage batteries. As a result of case studies, the simulator predicts that the frequency fluctuation varies greatly depending on the weather conditions and the fluctuation suppression parameters, even for the same configuration with the same power generation capacity. Therefore, it is preferable to increase the moving average time of the output and reduce the feedback gain of the storage battery to suppress the output fluctuation from the photovoltaics. However, there is a trade-off between suppressing the output fluctuation and the minimum required storage capacity. Furthermore, since the photovoltaics' output varies with the weather, other private generators' capacity and control parameters significantly impact power quality. The simulator proposed in this study makes it possible to study each hospital's desirable private generator configuration.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available