New Power Factor Correction Application for a Small Wind Power System

Journal

IEICE TRANSACTIONS ON ELECTRONICS
Volume E99C, Issue 5, Pages 581-589

Publisher

IEICE-INST ELECTRONICS INFORMATION COMMUNICATIONS ENG
DOI: 10.1587/transele.E99.C.581

Keywords

power factor correction; digital control; nonlinear-carrier control

Ask authors/readers for more resources

This study proposes the application and implementation of a new power factor correction (PFC) with a variable slope ramp for a small wind power system without any input voltage sensing circuits or external control components in the current shaping loop. The hardware description of the variable slope ramp simplifies the complexity of integrated circuit realization with low resolution analog-to-digital converters, and achieves a high power factor for multi and three-phase AC/DC converters such as wind power systems. Up to 1 kW small wind power system is tested to verify the performance of the proposed PFC control. The highest achieved power factor reaches 99.5%.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available