4.2 Editorial Material

Leadless pacemaker implantation complications and the denominator problem

Related references

Note: Only part of the references are listed.
Article Cardiac & Cardiovascular Systems

Major adverse clinical events associated with implantation of a leadless intracardiac pacemaker

Robert G. Hauser et al.

Summary: Leadless intracardiac pacemakers like the Medtronic Micra were developed to reduce complications. However, a study comparing MACE associated with Micra implantation to CapSureFix transvenous pacing leads found a higher incidence of major adverse clinical events with Micra, including higher rates of tamponade, death, and the need for rescue thoracotomies. Micra patients also had higher rates of complications such as requiring CPR and suffering from hypotension or shock compared to CapSureFix recipients.

HEART RHYTHM (2021)

Editorial Material Cardiac & Cardiovascular Systems

An emblematic defibrillator problem

Robert G. Hauser et al.

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY (2021)

Article Cardiac & Cardiovascular Systems

Contemporaneous Comparison of Outcomes Among Patients Implanted With a Leadless vs Transvenous Single-Chamber Ventricular Pacemaker

Jonathan P. Piccini et al.

Summary: This study compared patient characteristics and complications between patients implanted with leadless VVI and transvenous VVI pacemakers. Despite significant differences in patient characteristics, patients with leadless VVI pacemakers had higher rates of pericardial effusion and/or perforation but lower rates of other device-related complications and revisions at 6 months.

JAMA CARDIOLOGY (2021)

Article Medicine, General & Internal

A Leadless Intracardiac Transcatheter Pacing System

Dwight Reynolds et al.

NEW ENGLAND JOURNAL OF MEDICINE (2016)

Article Cardiac & Cardiovascular Systems

Complications after cardiac implantable electronic device implantations: an analysis of a complete, nationwide cohort in Denmark

Rikke Esberg Kirkfeldt et al.

EUROPEAN HEART JOURNAL (2014)

Article Cardiac & Cardiovascular Systems

Incidence and predictors of pacemaker reprogramming: potential consequences for remote follow-up

Erik O. Udo et al.

EUROPACE (2013)

Article Cardiac & Cardiovascular Systems

Randomized trial of pacemaker and lead system for safe scanning at 1.5 Tesla

J. Rod Gimbel et al.

HEART RHYTHM (2013)

Editorial Material Medicine, General & Internal

Postmarketing Surveillance of Medical Devices - Filling in the Gaps

Frederic S. Resnic et al.

NEW ENGLAND JOURNAL OF MEDICINE (2012)

Article Cardiac & Cardiovascular Systems

Multi-center clinical experience with a lumenless, catheter-delivered, bipolar, permanent pacemaker lead: Implant safety and electrical performance

Michael D. Gammage et al.

PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY (2006)

Article Cardiac & Cardiovascular Systems

Incidence and predictors of cardiac perforation after permanent pacemaker placement

S Mahapatra et al.

HEART RHYTHM (2005)

Article Cardiac & Cardiovascular Systems

Complications arising after implantation of DDD pacemakers: The MOST experience

KA Ellenbogen et al.

AMERICAN JOURNAL OF CARDIOLOGY (2003)