This nationwide population-based study investigated the safety of vitamin E-doped cross-linked polyethylene (VEPE) liners compared to other types of polyethylene in total hip arthroplasty (THA). The results showed that VEPE liners had a lower risk of revision for polyethylene-related issues compared to cross-linked liners (XLPE), but had a higher risk of all-cause revision within 3 months.
Background: Vitamin E-doped cross-linked polyethylene (VEPE) liners were introduced in total hip arthroplasty (THA) to reduce wear and risk of aseptic loosening and liner fracture. We report this nationwide population-based study to investigate the safety of VEPE liners for THA compared to cross linked annealed or remelted polyethylene (XLPE). Methods: We included THAs from The Danish Hip Arthroplasty Register from January 1, 2008 to June 30, 2019, with uncemented cup, VEPE or XLPE liner, and metal or ceramic head. The outcome was revision due to (1) polyethylene-related endpoints (aseptic loosening, granuloma, osteolysis, or liner fractures) and (2) other endpoints. Results: A total of 110,803 THAs were assessed for eligibility and 53,842 THAs (46,645 patients) were included in the study: 5069 (9.4%) THAs with a VEPE liner and 48,773 (91.6%) with a XLPE liner. Median observation time was 5.48 (interquartile range 3.80-7.15) years for VEPE and 4.85 (interquartile range 2.68-7.76) for XLPE. VEPE had a lower risk of revision for polyethylene-related endpoints compared to XLPE (hazard ratio [HR] 0.60, 95% confidence interval 0.36-0.98) during complete follow-up. THAs with VEPE liners were associated with increased risk of any revision within the first 3 months (HR 1.62, 1.36-1.94), revision recorded as aseptic loosening within 3 months (HR 4.46, 2.26-8.80), and periprosthetic fracture within 3 months (HR 2.57, 1.98, 3.33). Conclusion: VEPE liners had a lower risk of revision due to polyethylene-related endpoints, but a higher risk of all-cause revision within 3 months. ?? 2022 The Authors. Published by Elsevier Inc. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available