4.6 Article

Permanent Pacemaker Reduction Using Cusp-Overlapping Projection in TAVR

Journal

JACC-CARDIOVASCULAR INTERVENTIONS
Volume 15, Issue 2, Pages 150-161

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jcin.2021.10.002

Keywords

cusp overlapping; implantation depth; permanent pacemaker implantation; self-expanding; transcatheter aortic valve replacement

Ask authors/readers for more resources

This study aimed to determine whether modifying the implantation technique for self-expanding transcatheter aortic valve replacement results in a higher implantation depth and reduces the rate of permanent pacemaker implantation.
OBJECTIVES The aim of this study was to determine if modifying the classical implantation technique for self-expanding (SE) transcatheter aortic valve replacement to a novel cusp-overlapping projection (COP) technique results in a higher implantation depth (ID) and subsequently reduces the rate of permanent pacemaker implantation (PPMI). BACKGROUND The COP technique presents the potential benefit of an optimized ID to reduce the rate of PPMI. However, only a few studies have compared clinical outcomes with those achieved using the standard technique. This is the first study to systematically evaluate this approach for SE transcatheter heart valves (THVs) in different populations METHODS Beginning in February 2015, 444 patients were consecutively included. Propensity score matching was used to control baseline characteristics because of the observational nature of the study. In total, 161 pairs of patients were analyzed. Three methods were used to measure ID (noncoronary cusp [NCC] to the THV, mean of the NCC and the left coronary cusp [LCC] to the THV, and the deepest edge from the LCC and the NCC to the THV). RESULTS ID was significantly higher in COP cases when measuring from the NCC (4.2 mm vs 5.3 mm; P < 0.001) and the mean from the NCC and the LCC (5.3 mm vs 5.9 mm; P = 0.04), but not from the deepest edge. The PPMI rate was lower in the COP group: 19 (11.8%) vs 35 (21.7%) (P = 0.03; relative risk: 0.54; 95% CI: 0.32-0.91). CONCLUSIONS The present study showed that the COP technique significantly reduces PPMI in SE THV implantation compared with the classical implantation technique, with similar rates of complications. (J Am Coll Cardiol Intv 2022;15:150-161) (c) 2022 by the American College of Cardiology Foundation.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available