4.7 Article

A paper-based self-pumping microfluidic fuel cell stack with a novel vertical structure

Journal

INTERNATIONAL JOURNAL OF ENERGY RESEARCH
Volume 46, Issue 6, Pages 8389-8397

Publisher

WILEY
DOI: 10.1002/er.7742

Keywords

microfluidic fuel cell stack; paper capillary; self-pumping; vertical stack configuration

Funding

  1. Qinglan Engineering Project of Jiangsu Universities
  2. Natural Science Research Project of Higher Education Institutions in Government of Jiangsu Province [20KJA480005]
  3. Hong Kong Research Grants Council/General Research Fund [11206520]
  4. Research and Innovation initiatives of WHPU [2020 J05]
  5. China Postdoctoral Science Foundation [2020 M673395]
  6. National Natural Science Foundation of China [51806241, 51905236]

Ask authors/readers for more resources

In this study, a novel paper-based self-pumping MFC stack with potassium formate and hydrogen peroxide as the fuel and oxidant, respectively, was proposed. Passive liquid flow was achieved through capillary action, and a compact vertical stack structure was adopted to reduce costs. Experimental results showed significantly improved power output in the stack prototypes, which was attributed to enhanced capillary flows and reduced ohmic losses in the vertical stacking structure. Additionally, it was found that a loose microstructure of the paper wick contributed to enhanced mass transfer.
Microfluidic fuel cell (MFC) stacking is a prerequisite to enhance its power output for practical applications. However, most MFC stacks reported in the present literature require external pumps to maintain the co-laminar flow and complex fluidic management networks for homogeneous flow and reactant distributions. To address these issues, a novel paper-based self-pumping MFC stack with potassium formate as the fuel and hydrogen peroxide as the oxidant is proposed in this study. The capillary action is employed to achieve passive liquid flow. A vertical stack structure with the unit cells piled one above another compactly is adopted to reduce the volumetric costs. The experimental results show that the maximum power outputs of the two-cell and three-cell stack prototypes are 4.01 and 7.26 mW cm(-2), outperforming the MFC unit by 5.81 and 10.52 times, respectively. The superior performance is attributed to its distinct vertical stacking structure, which brings the enhanced capillary flows in the paper wicks and reduced ohmic losses in comparison with the unit cell. Further, effects of the filter paper and reactant concentrations on the stack performance were examined, and mass transfer of the fuel and/or oxidant to the electrode/electrolyte interface was identified as the main limiting factor. A loose microstructure of the paper wick was found beneficial in enhancing the mass transfer. The potential applications of the MFC stack in a variety of portable electronics are broad.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available