Dynamic Voltage Support for Low-Voltage Ride-Through Operation in Single-Phase Grid-Connected Photovoltaic Systems

Journal

IEEE TRANSACTIONS ON POWER ELECTRONICS
Volume 36, Issue 10, Pages 12102-12111

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TPEL.2021.3073589

Keywords

Voltage control; Inverters; Power system stability; Power harmonic filters; Synchronization; Power quality; Low voltage; Dynamic voltage support (DVS); low-voltage ride-through (LVRT); reactive power control; single-phase grid-connected photovoltaic (PV) system

Ask authors/readers for more resources

This article proposes a dynamic voltage support scheme for achieving low-voltage ride-through using a grid-connected photovoltaic inverter. The scheme involves an additional control mode developed from conventional reactive current control approach, leading to stable operation and improved effectiveness in low-voltage networks. Results show that the proposed controller meets grid code requirements for regulating active and reactive power during symmetrical faults, allowing for fast transient events and preventing unwanted grid disconnections.
This article presents a dynamic voltage support (DVS) scheme for achieving low-voltage ride-through (LVRT) with a grid-connected photovoltaic (PV) inverter during the voltage sag fault. The DVS scheme is achieved by formulating an additional reactive active current control mode which is developed from a conventional reactive current control approach. This provides stable operation of the system and achieves higher effectiveness due to the lower X/R ratio at the point of common coupling in low-voltage networks. Further, the performance of the proposed controller is assessed by simulating a 4 kW system for voltage sag faults. Further, the proposed controller tested with the real-time simulations and experimental setup for voltage sag conditions. The results presented demonstrate that the active and reactive power is regulated in concordance with grid code requirements. The controller achieves LVRT within the time limits of grid standard during symmetrical faults, which makes it appropriate for fast transient events. This operates the PV system under its nominal capacity, avoiding unwanted grid disconnection events.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available