4.7 Article

Computational Breast Anatomy Simulation Using Multi-Scale Perlin Noise

Journal

IEEE TRANSACTIONS ON MEDICAL IMAGING
Volume 40, Issue 12, Pages 3436-3445

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TMI.2021.3087958

Keywords

Breast; Phantoms; Imaging phantoms; Ligaments; Noise measurement; Computational modeling; Clinical trials; Perlin noise; virtual clinical trial; anthropomorphic breast phantom; digital breast tomosynthesis

Funding

  1. Department of Defense Breast Cancer Research Program [W81XWH-18-1-0082]
  2. Burroughs Wellcome Fund (BWF) [IRSA 1016451]
  3. American Association of Physicists in Medicine
  4. National Institute of Health (NIH) [NIH R01 CA154444, NIH R01 EB018958, NIH R01-EB025829]
  5. Komen Foundation [IIR-13262248]

Ask authors/readers for more resources

This study proposed a technique using Perlin noise method to simulate the structure of breast tissue, which can be used in virtual clinical trials for breast imaging. The images simulated using this method showed similar power-law spectra compared to clinical mammograms, and were able to better simulate breast anatomical noise.
Virtual clinical trials (VCTs) of medical imaging require realistic models of human anatomy. For VCTs in breast imaging, a multi-scale Perlin noise method is proposed to simulate anatomical structures of breast tissue in the context of an ongoing breast phantom development effort. Four Perlin noise distributions were used to replace voxels representing the tissue compartments and Cooper's ligaments in the breast phantoms. Digital mammography and tomosynthesis projections were simulated using a clinical DBT system configuration. Power-spectrum analyses and higher-order statistics properties using Laplacian fractional entropy (LFE) of the parenchymal texture are presented. These objective measures were calculated in phantom and patient images using a sample of 140 clinical mammograms and 500 phantom images. Power-law exponents were calculated using the slope of the curve fitted in the low frequency [0.1, 1.0] mm(-1) region of the power spectrum. The results show that the images simulated with our prior and proposed Perlin method have similar power-law spectra when compared with clinical mammograms. The power-law exponents calculated are -3.10, -3.55, and -3.46, for the log-power spectra of patient, prior phantom and proposed phantom images, respectively. The results also indicate an improved agreement between the mean LFE estimates of Perlin-noise based phantoms and patients than our prior phantoms and patients. Thus, the proposed method improved the simulation of anatomic noise substantially compared to our prior method, showing close agreement with breast parenchyma measures.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available