4.4 Article

Optimal Transmit Coil Design for Wirelessly Powered Biomedical Implants Considering Magnetic Field Safety Constraints

Related references

Note: Only part of the references are listed.
Article Engineering, Electrical & Electronic

Magnetoelectric wireless power transfer for biomedical implants: Effects of non-uniform magnetic field, alignment and orientation

Binh Duc Truong et al.

SENSORS AND ACTUATORS A-PHYSICAL (2020)

Article Engineering, Electrical & Electronic

Experimental study of magnetoelectric transducers for power supply of small biomedical devices

Kevin Malleron et al.

MICROELECTRONICS JOURNAL (2019)

Proceedings Paper Energy & Fuels

OPTIMAL COIL DESIGN FOR WIRELESS POWERING OF BIOMEDICAL IMPLANTS CONSIDERING SAFETY CONSTRAINTS

Erik Andersen et al.

2019 IEEE MTT-S WIRELESS POWER TRANSFER CONFERENCE (WPTC) / IEEE PELS WORKSHOP ON EMERGING TECHNOLOGIES: WIRELESS POWER (WOW) / WIRELESS POWER WEEK (WPW 2019) (2019)

Proceedings Paper Engineering, Electrical & Electronic

Potentiality of magnetoelectric composites for Wireless Power Transmission in medical implants

Giulia Rizzo et al.

2019 13TH INTERNATIONAL SYMPOSIUM ON MEDICAL INFORMATION AND COMMUNICATION TECHNOLOGY (ISMICT) (2019)

Article Multidisciplinary Sciences

Acoustically actuated ultra-compact NEMS magnetoelectric antennas

Tianxiang Nan et al.

NATURE COMMUNICATIONS (2017)

Article Engineering, Electrical & Electronic

Optimization of Coreless Electromagnets to Maximize Field Generation for Magnetic Manipulation Systems

Jake J. Abbott et al.

IEEE MAGNETICS LETTERS (2017)

Article Engineering, Electrical & Electronic

Energy Recycling Telemetry IC With Simultaneous 11.5 mW Power and 6.78 Mb/s Backward Data Delivery Over a Single 13.56 MHz Inductive Link

Sohmyung Ha et al.

IEEE JOURNAL OF SOLID-STATE CIRCUITS (2016)

Article Engineering, Biomedical

Optimal Design of Wireless Power Transmission Links for Millimeter-Sized Biomedical Implants

Dukju Ahn et al.

IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS (2016)

Article Chemistry, Multidisciplinary

Ubiquitous magneto-mechano-electric generator

Jungho Ryu et al.

ENERGY & ENVIRONMENTAL SCIENCE (2015)

Article Automation & Control Systems

Wireless Power Transmission With Self-Regulated Output Voltage for Biomedical Implant

Dukju Ahn et al.

IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS (2014)

Article Multidisciplinary Sciences

Wireless power transfer to deep-tissue microimplants

John S. Ho et al.

PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA (2014)

Article Engineering, Biomedical

A Low-Frequency Versatile Wireless Power Transfer Technology for Biomedical Implants

Hao Jiang et al.

IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS (2013)

Article Engineering, Electrical & Electronic

High-Efficiency Wireless Power Transfer for Biomedical Implants by Optimal Resonant Load Transformation

Rui-Feng Xue et al.

IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS (2013)

Article Engineering, Electrical & Electronic

Midfield Wireless Powering for Implantable Systems

John S. Ho et al.

PROCEEDINGS OF THE IEEE (2013)

Article Physics, Applied

Tunable self-biased magnetoelectric response in homogenous laminates

Yuan Zhou et al.

APPLIED PHYSICS LETTERS (2012)

Article Engineering, Electrical & Electronic

Implantable Biomedical Devices: Wireless Powering and Communication

Anatoly Yakovlev et al.

IEEE COMMUNICATIONS MAGAZINE (2012)

Article Engineering, Electrical & Electronic

A 3-μW CMOS Glucose Sensor for Wireless Contact-Lens Tear Glucose Monitoring

Yu-Te Liao et al.

IEEE JOURNAL OF SOLID-STATE CIRCUITS (2012)

Article Engineering, Electrical & Electronic

Powering a Ventricular Assist Device (VAD) With the Free-Range Resonant Electrical Energy Delivery (FREE-D) System

Benjamin H. Waters et al.

PROCEEDINGS OF THE IEEE (2012)

Article Engineering, Biomedical

Design and Optimization of Resonance-Based Efficient Wireless Power Delivery Systems for Biomedical Implants

Anil Kumar RamRakhyani et al.

IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS (2011)

Article Engineering, Electrical & Electronic

Optimal Frequency for Wireless Power Transmission Into Dispersive Tissue

Ada S. Y. Poon et al.

IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION (2010)

Article Engineering, Electrical & Electronic

CALCULATION OF THE MAGNETIC FIELD CREATED BY A THICK COIL

R. Ravaud et al.

JOURNAL OF ELECTROMAGNETIC WAVES AND APPLICATIONS (2010)

Article Engineering, Electrical & Electronic

Improved wireless, transcutaneous power transmission for in vivo applications

Robert C. O'Handley et al.

IEEE SENSORS JOURNAL (2008)

Article Acoustics

Longitudinal and transverse magnetoelectric voltage coefficients of magnetostrictive/piezoelectric laminate composite: Experiments

SX Dong et al.

IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL (2004)

Article Engineering, Electrical & Electronic

Optimal design and construction of a lightweight minimum-power solenoid magnet

PN Morgan

IEEE TRANSACTIONS ON MAGNETICS (2001)