4.6 Article

Robust R-Peak Detection in Low-Quality Holter ECGs Using 1D Convolutional Neural Network

Journal

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING
Volume 69, Issue 1, Pages 119-128

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TBME.2021.3088218

Keywords

Electrocardiography; Sensitivity; Performance evaluation; Monitoring; Benchmark testing; Noise measurement; Electronic mail; 1D convolutional neural network; R-peak detection; ECG monitoring; holter registers

Funding

  1. Qatar National Research Fund [NPRP11S-0108-180228]
  2. Academy of Finland under Project AWcHA

Ask authors/readers for more resources

The study proposes a generic and robust system for R-peak detection in Holter ECG signals using a 1D Convolutional Neural Network. Experimental results show high detection performance on two open-access ECG databases. The proposed approach significantly reduces false-positives and false-negatives in Holter ECG signals compared to competing methods.
Objective: Noise and low quality of ECG signals acquired from Holter or wearable devices deteriorate the accuracy and robustness of R-peak detection algorithms. This paper presents a generic and robust system for R-peak detection in Holter ECG signals. While many proposed algorithms have successfully addressed the problem of ECG R-peak detection, there is still a notable gap in the performance of these detectors on such low-quality ECG records. Methods: In this study, a novel implementation of the 1D Convolutional Neural Network (CNN) is used integrated with a verification model to reduce the number of false alarms. This CNN architecture consists of an encoder block and a corresponding decoder block followed by a sample-wise classification layer to construct the 1D segmentation map of R-peaks from the input ECG signal. Once the proposed model has been trained, it can solely be used to detect R-peaks possibly in a single channel ECG data stream quickly and accurately, or alternatively, such a solution can be conveniently employed for real-time monitoring on a lightweight portable device. Results: The model is tested on two open-access ECG databases: The China Physiological Signal Challenge (2020) database (CPSC-DB) with more than one million beats, and the commonly used MIT-BIH Arrhythmia Database (MIT-DB). Experimental results demonstrate that the proposed systematic approach achieves 99.30% F1-score, 99.69% recall, and 98.91% precision in CPSC-DB, which is the best R-peak detection performance ever achieved. Results also demonstrate similar or better performance than most competing algorithms on MIT-DB with 99.83% F1-score, 99.85% recall, and 99.82% precision. Significance: Compared to all competing methods, the proposed approach can reduce the false-positives and false-negatives in Holter ECG signals by more than 54% and 82%, respectively. Conclusion: Finally, the simple and invariant nature of the parameters leads to a highly generic system and therefore applicable to any ECG dataset.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available