Journal
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY
Volume 31, Issue 8, Pages -Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TASC.2021.3108737
Keywords
MVDC SPS; SFCL; short circuit fault; system simulation
Ask authors/readers for more resources
This paper examines the evolution of short-circuit faults in typical MVDC SPS and proposes a SCLS topology with a superconducting coupled coil and two DCCBs. By establishing models on MATLAB/Simulink, the current limiting and current sharing principles of SCLS are verified, demonstrating effective current limiting performance and fault clearing effect.
The medium voltage direct current (MVDC) is a promising direction of future shipboard power system (SPS). However, one of the main limitations encountered in its development is the fault isolation of DC side. This paper reveals the evolution process of short-circuit fault in typical MVDC SPS through equivalent circuit and transient simulation. Based on the analysis of protection needs, a superconducting current-limiting switch (SCLS) topology is proposed, which includes one superconducting coupled coil and two DC circuit breakers (DCCBs). The models of SCLS is built on MATLAB/Simulink and the current limiting principle and current sharing principle of SCLS are verified. The results show that the SCLS has effective current limiting performance and fault clearing effect.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available