4.7 Article

Highly Sensitive Room-Temperature Ammonia Sensors Based on Single-Wall Carbon Nanotubes Modified by PEDOT

Journal

IEEE SENSORS JOURNAL
Volume 22, Issue 4, Pages 3024-3032

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JSEN.2022.3142405

Keywords

Sensors; Ammonia; Temperature sensors; Carbon nanotubes; Gas detectors; Dispersion; Solvents; PEDOT; carbon nanotubes; sulfonic group; ammonia; gas sensor

Funding

  1. European Regional Development Fund through the Operational Programme Research, Development and Education (OP RDE) by the Project Carbon allotropes with rationalized nanointerfaces and nanolinks for environmental and biomedical applications [CZ.02.1.01/0.0/0.0/16_026/0008382]
  2. Czech Science Foundation (GACR) (Organic gas sensorsnovel structures, electrical parameters, properties, and operation) [20-03913S]

Ask authors/readers for more resources

An ammonia gas sensor material based on sulfonic functionalized single-wall carbon nanotubes modified by poly(3,4-ethylenedioxythiophene) was prepared and its sensing performance was studied. The sensor showed excellent response to ammonia at room temperature and the ability to detect ammonia at sub-ppm concentration.
An ammonia gas sensor material based on sulf- onic functionalized single-wall carbon nanotubes modified by poly(3,4-ethylenedioxythiophene), namely, PEDOT/SWCNT-SO3H, was prepared via in situ polymerization. A thin active layer of PEDOT/SWCNT-SO3H was deposited on a polyimide substrate with interdigital electrodes by air-brush spray coating. The morphology of the prepared material was studied by scanning electron microscopy, and the presence of PEDOT in the structure of SWCNT-SO3H was examined with Raman spectroscopy. The obtained results showed that PEDOT was successfully bound to SWCNT-SO3H and that this modification significantly improved the NH3 sensing performance of the sensor. The sensor exhibited a strong response to ammonia (102% at 50 ppm), minimal drift in the electrical resistance during cyclic exposure, and good spontaneous desorption, all at room temperature. In the range from 20 ppm to 100 ppm ammonia, the calibration curve is considered linear, with a sensitivity of a 0.7% resistance change per 1 ppm ammonia. Furthermore, the sensor shows the ability to detect ammonia at sub-ppm concentration, and the response is 4.4% at 300 ppb. With regard to the material structure, the sensing mechanisms of both materials, i.e., PEDOT/SWCNT-SO3H and SWCNT-SO3H, are discussed in the article.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available