4.7 Article

Optimisation of an Electrical Impedance Sensor for Use in Microfluidic Chip Electrophoresis

Related references

Note: Only part of the references are listed.
Article Engineering, Electrical & Electronic

Modeling the Impact of Sensitivity Distribution Variations of Tetrapolar Impedance Configurations in Microfluidic Analytical Devices

Martin Hantschke et al.

Summary: This study investigates the effects of electrode topology and configuration on tetrapole electrical impedance measurement systems in microfluidic devices. Different electrode configurations were found to exhibit fundamental differences in sensitivity distribution, affecting performance when measuring heterogeneous fluids.

IEEE SENSORS JOURNAL (2021)

Review Chemistry, Analytical

A decade of microchip electrophoresis for clinical diagnostics - A review of 2008-2017

Alain Wuethrich et al.

ANALYTICA CHIMICA ACTA (2019)

Article Chemistry, Analytical

Zonal selectivity by sensitivity modulation in linear tetrapolar impedance sensors

Fabian N. Moretti et al.

SENSORS AND ACTUATORS B-CHEMICAL (2018)

Review Biochemical Research Methods

Derivatisation for separation and detection in capillary electrophoresis (2012-2015)

Alain Wuethrich et al.

ELECTROPHORESIS (2016)

Review Biochemical Research Methods

Present state of microchip electrophoresis: State of the art and routine applications

Eric R. Castro et al.

JOURNAL OF CHROMATOGRAPHY A (2015)

Review Chemistry, Analytical

Recent applications of microchip electrophoresis to biomedical analysis

Nantana Nuchtavorn et al.

JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS (2015)

Article Chemistry, Analytical

Planar sensors for local conductivity measurements in biological objects-Design, modelling, sensitivity maps

Tomasz Grysinski et al.

SENSORS AND ACTUATORS B-CHEMICAL (2011)

Article Computer Science, Interdisciplinary Applications

Platinum electrode noise in the ENG spectrum

Xiao Liu et al.

MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING (2008)

Article Chemistry, Analytical

On-chip contactless four-electrode conductivity detection for capillary electrophoresis devices

F Laugere et al.

ANALYTICAL CHEMISTRY (2003)

Article Chemistry, Analytical

Comparison of different conductivity detector geometries on an isotachophoresis PMMA-microchip

B Grass et al.

FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY (2001)

Article Engineering, Electrical & Electronic

Bipolar and tetrapolar transfer impedance measurements from volume conductor

BH Brown et al.

ELECTRONICS LETTERS (2000)