4.7 Article

Towards Personalized Statistical Deformable Model and Hybrid Point Matching for Robust MR-TRUS Registration

Journal

IEEE TRANSACTIONS ON MEDICAL IMAGING
Volume 35, Issue 2, Pages 589-604

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TMI.2015.2485299

Keywords

Deformable registration; statistical deformable model; robust point matching; elastography; MR-TRUS prostate registration

Funding

  1. National Basic Research Program of China, 973 Program [2015CB351706]
  2. Ministry of Science and Technology of the People's Republic of China under the Singapore-China 9th Joint Research Programe [2013DFG12900]
  3. Research Grants Council of Hong Kong [CUHK 14202514]
  4. National Science Foundation of China [61571304]
  5. Shenzhen-Hong Kong Innovation Circle Funding Program [JSE201109150013A]

Ask authors/readers for more resources

Registration and fusion of magnetic resonance (MR) and 3D transrectal ultrasound (TRUS) images of the prostate gland can provide high-quality guidance for prostate interventions. However, accurate MR-TRUS registration remains a challenging task, due to the great intensity variation between two modalities, the lack of intrinsic fiducials within the prostate, the large gland deformation caused by the TRUS probe insertion, and distinctive biomechanical properties in patients and prostate zones. To address these challenges, a personalized model-to-surface registration approach is proposed in this study. The main contributions of this paper can be threefold. First, a new personalized statistical deformable model (PSDM) is proposed with the finite element analysis and the patient-specific tissue parameters measured from the ultrasound elastography. Second, a hybrid point matching method is developed by introducing the modality independent neighborhood descriptor (MIND) to weight the Euclidean distance between points to establish reliable surface point correspondence. Third, the hybrid point matching is further guided by the PSDM for more physically plausible deformation estimation. Eighteen sets of patient data are included to test the efficacy of the proposed method. The experimental results demonstrate that our approach provides more accurate and robust MR-TRUS registration than state-of-the-art methods do. The averaged target registration error is 1.44 mm, which meets the clinical requirement of 1.9 mm for the accurate tumor volume detection. It can be concluded that the presented method can effectively fuse the heterogeneous image information in the elastography, MR, and TRUS to attain satisfactory image alignment performance.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available