4.7 Article

Thermodynamic assessment of the novel concept of the energy storage system using compressed carbon dioxide, methanation and hydrogen generator

Journal

FUEL
Volume 304, Issue -, Pages -

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.fuel.2021.120764

Keywords

Energy storage; Compressed carbon dioxide; Hydrogen generators; Methanation; Coal mines

Funding

  1. National Science Centre [2017/27/B/ST8/02270]

Ask authors/readers for more resources

This paper characterizes a novel energy storage system based on compressed CO2 storage installation, utilizing depleted coal mines as infrastructure and incorporating hydrogen generators and methanation installation to generate synthetic natural gas. Through mathematical modeling and thermodynamic evaluation, the system demonstrates a storage efficiency ranging from 35.06% to 63.93%, indicating high storage potential in regions with underground mine infrastructure.
The main aim of this paper is to characterize the concept of a novel energy storage system, based on compressed CO2 storage installation, that uses an infrastructure of depleted coal mines to provide required volume of tanks, and, additionally, hydrogen generators, and a methanation installation to generate synthetic natural gas that can be used within the system or taken out of it, e.g., to a gas grid. A detailed mathematical model of the proposed solution was built using own codes and Aspen Plus software. Thermodynamic evaluation, aiming at determining parameters, composition and streams in all the most important nodes of the system for the nominal point and when changing a defined decision variable delta (in the range from 0.1 to 0.9) was made. The evaluation was made based on the storage efficiency, volume of the tanks and flows of energy within the system. The storage efficiency in the nominal point reached 45.08%, but was changing in the range from 35.06% (for delta = 0.1) to 63.93% (for delta = 0.9). For the nominal value of delta, equal to 0.5, volume of the low-pressure tank (LPT) was equal to 132,869 m(3), while of the high pressure tank (HPT) to 1219 m(3). When changing delta these volumes were changing from 101,900 m(3) to 190,878 m(3) (for LPT), and from 935 to 1751 m(3) (for HPT), respectively. Detailed results are presented in the paper and indicate high storage potential of the proposed solution in regions with underground mine infrastructure.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available