4.7 Article

Sensitive and selective electrochemical detection of bisphenol A based on SBA-15 like Cu-PMO modified glassy carbon electrode

Journal

FOOD CHEMISTRY
Volume 358, Issue -, Pages -

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.foodchem.2021.129763

Keywords

Sensor; Bisphenol A; Periodic mesoporous organosilica (PMO); Glassy carbon electrode

Funding

  1. Maragheh University of Medical Sciences [IR.MARAGHEHPHC.REC.1398.021]

Ask authors/readers for more resources

This work describes a novel electrochemical sensor based on Cu functionalized SBA-15 like periodic mesoporous organosilica-ionic liquid composite for the sensitive detection of bisphenol A (BPA). The sensor showed a linear detection range for BPA, high stability, and accuracy of results when applied to detect BPA in environmental samples, making it a powerful tool for rapid and sensitive detection of BPA.
This work reports the electrochemical detection of bisphenol A (BPA) using a novel and sensitive electrochemical sensor based on the Cu functionalized SBA-15 like periodic mesoporous organosilica-ionic liquid composite modified glassy carbon electrode (Cu@TU-PMO/IL/GCE). The structural morphology of Cu@TU-PMO is characterized by X-ray powder diffraction (XRD), energy dispersive X-ray analysis (EDX), Fourier transform infrared spectroscopy (FT-IR), transmission electron microscopy (TEM), Field emission scanning electron microscopy (FESEM), and Brunauer-Emmett-Teller (BET). The catalytic activity of the modified electrode toward oxidation of BPA was interrogated with cyclic voltammetry (CV) and differential pulse voltammetry (DPV) in phosphate buffer solution (pH 7.0) using the fabricated sensor. The electrochemical detection of the analyte was carried out at a neutral pH and the scan rate studies revealed that the sensor was stable. Under the optimal conditions, a linear range from 5.0 nM to 2.0 mu M and 4.0 to 500 mu M for detecting BPA was observed with a detection limit of 1.5 nM (S/N = 3). The sensor was applied to detect BPA in tap and seawater samples, and the accuracy of the results was validated by high-performance liquid chromatography (HPLC). The proposed method provides a powerful tool for the rapid and sensitive detection of BPA in environmental samples.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available