4.7 Article

Preoperative prediction for mastoid extension of middle ear cholesteatoma using temporal subtraction serial HRCT studies

Journal

EUROPEAN RADIOLOGY
Volume 32, Issue 6, Pages 3631-3638

Publisher

SPRINGER
DOI: 10.1007/s00330-021-08453-0

Keywords

Cholesteatoma; Ear, middle; Mastoid; Tomography, x-ray computed

Ask authors/readers for more resources

This study investigates the utility of temporal subtraction computed tomography (TSCT) obtained with temporal bone high-resolution computed tomography (HRCT) for the preoperative prediction of mastoid extension of middle ear cholesteatomas. The results show that TSCT with black color has high sensitivity and specificity, and HRCT also has certain accuracy in detecting the width of the anterior part of the mastoid.
Objectives This study investigated the utility of temporal subtraction computed tomography (TSCT) obtained with temporal bone high-resolution computed tomography (HRCT) for the preoperative prediction of mastoid extension of middle ear cholesteatomas. Methods Twenty-eight consecutive patients with surgically proven middle ear cholesteatomas were retrospectively evaluated. The presence of black color in the mastoid region on TSCT suggested progressive changes caused by bone erosion. Enlarged width of the anterior part of mastoid on HRCT was interpreted as suggestive of mastoid extension. Fisher's exact test was used to compare the widths and black color on TSCT for cases with and without mastoid extension. The diagnostic accuracy of TSCT and HRCT for detecting mastoid extension and interobserver agreement during the evaluation of black color on TSCT were calculated. Results There were 15 cases of surgically proven mastoid extension and 13 cases without mastoid extension. Patients with black color on TSCT were significantly more likely to have a mastoid extension (p < 0.001). The sensitivity and specificity of TSCT were 0.93 and 1.00, respectively. Patients in whom the width of the anterior part of the mastoid was enlarged were significantly more likely to have a mastoid extension (p = 0.007). The sensitivity and specificity of HRCT to detect the width of the anterior part of the mastoid were 0.80 and 0.77, respectively. Interobserver agreement during the evaluation of TSCT findings was good (k = 0.71). Conclusions This novel TSCT technique and preoperative evaluations are useful for assessing mastoid extension of middle ear cholesteatomas and making treatment decisions.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available