Assessing patent ductus arteriosus in preterm infants from standard neonatal intensive care monitoring

Journal

EUROPEAN JOURNAL OF PEDIATRICS
Volume 181, Issue 3, Pages 1117-1124

Publisher

SPRINGER
DOI: 10.1007/s00431-021-04311-9

Keywords

Echocardiography; Biomarkers; Haemodynamics; Patent ductus arteriosus; Preterm infants

Categories

Funding

  1. Neocirculation Consortium (European FP7-Grant) [282533]

Ask authors/readers for more resources

Monitoring patent ductus arteriosus (PDA) in premature infants using standard neonatal monitoring, including ECG and blood pressure waveform analysis, may provide potential biomarkers for continuous evaluation of PDA diameter and function. The study found significant correlations between PDA diameter and various parameters derived from ECG and blood pressure waveforms, suggesting a promising approach for assessing PDA status.
Monitoring patent ductus arteriosus (PDA) in premature infants is currently performed intermittently using echocardiography which requires considerable expertise. The aim of this pilot study was to investigate whether PDA status could be assessed from standard neonatal intensive care monitoring. Electrocardiography (ECG) and blood pressure (BP) waveforms were acquired from extremely preterm infants using standard neonatal monitors. We developed software using MATLAB to analyse ECG and BP waveforms and their interrelationships in terms of pulse transit time (PTT) and pulse wave velocity (PWV). The times from peak systolic BP to diastolic trough (BPFt) and from the diastolic trough to peak systolic BP (BPRt) were also calculated. PTT, BPFt and BPRt were normalised for heart rate (HR) termed NPTT, NBPFt and NBPRt, respectively. ECG, invasive aortic BP monitoring and echocardiography were performed in 14 preterm infants < 29 weeks' gestation in the first 3 days after birth. The median (range) birth weight of the infants was 0.90 (0.48-1.31) kg, gestation 26.6 (24.0-28.7) weeks, PDA diameter 1.6 (0.8-3.6) mm and mean BP 32 (16-40) mmHg. We found a significant positive correlation between PDA diameter and NPTT (r = 0.69, P = 0.007) as well as NBPFt (r = 0.65, P = 0.012) and NBPRt (r = 0.71, P = 0.005). No relationship was found between PDA diameter and pulse pressure. Conclusions: Interrelationships between ECG and BP traces as well as BP waveform time analysis are straightforward to measure and associated with PDA diameter. The results of this pilot study suggest that this approach may help provide biomarkers for continuous monitoring PDA diameter and function.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available